Canford 58-321 Arkusz danych technicznych - Strona 2

Przeglądaj online lub pobierz pdf Arkusz danych technicznych dla Jednostka sterująca Canford 58-321. Canford 58-321 3 stron. Ppm drive card

PIN LAYOUTS
PIN LAYOUTS
1
External Meter +ve
1 External Meter +ve
2
External Meter -ve
2 External Meter -ve
3
Slow Mode Switch
4
Common LED -ve / Slow Mode Switch
3 Slow Mode Switch
5
Peak LED +ve
4 Common LED -ve / Slow Mode Switch
6
Signal IN +ve
5 Peak LED +ve
7
Signal IN -ve
6 Signal IN +ve
8
Common
9
Power Supply +ve
7 Signal IN -ve
10
Power Supply 0V/-ve
8 Common
9 Power Supply +ve
10 Power Supply 0V/-ve
PL1 WIRING
PL1 WIRING
Balanced Input, Single Rail Power
Balanced Input, Single Rail Power
Audio
Balanced Input, Dual Rail Power
Balanced Input, Dual Rail Power
Audio
PSU 0V
02-074(Issue 4)01/01
CANFORD GROUP LTD, Elliott House, Crowther Road, Washington, Tyne & Wear, NE38 0BW, UK
CANFORD AUDIO PLC
CROWTHER ROAD WASHINGTON
TYNE & WEAR NE38 OBW, UK
admin (0191)418 1000
sales (0191)418 1122
fax (0191)418 1001
1K8
Meter
Slow Mode
Meter (Red) Peak
PSU +
PSU 0V
PSU +
PSU -
Fig. 1 – Meter, Audio & Power Connections
Fig. 1 – Meter, Audio & Power Connections
technical data
1
P L 1
C o n n e c t o r v i e w e d f r o m c o m p o n e n t s i d e .
Connector viewed from component side.
470µF required ONLY if external
meter is used in slow mode
1K
*
2.2µF
470µF
Un-balanced Input, Single Rail Power
Un-balanced Input, Single Rail Power
6
Audio
7
8
9
PSU 0V
10
Un-balanced Input, Dual Rail Power
Un-balanced Input, Dual Rail Power
6
Audio
7
8
9
PSU 0V
10
canford.co.uk
1 0
1
2
3
4
5
6
7
8
PSU +
9
10
6
7
8
PSU +
9
PSU -
10
02-074 Issue 6