4. MULTIFUNCTION KIT CONNECTION
Switch off the unit.
Type A terminal board connection
 ON / OFF remote (available in 2 different versions):
Version 1 (connect ON/OFF1 - ON/OFF2)

The contact is normally open

When the contact closes, if the unit is switched off it will remain
off; if it is on, it goes out.

When the contact opens, if the unit is switched off, it lights up; if it
is on, it stays on.

The status of the contact and of the unit do not always
correspond since from the remote control it is possible to force
the status set by the contact and vice versa. ES. If the unit is
switched off by the remote control and the contact is closed (off)
and reopened (on) the unit will switch back on with setpoint 24°C
even if the remote control is switched off.

Every opening and closing of the contact involves a reset both of
the set-point which returns to 24 °C and of the setting dates given
by the remote control.

The unit can be controlled normally with the remote control
Version 2 (connect SWITCH1 - SWITCH2)

The contact is normally closed

When the contact opens, the unit switches off.
The unit can not be controlled with the remote control by trying to
switch it on with this, "CP" will appear on the display.

When the contact closes, the unit can be controlled with the re-
mote control.
The user can control the unit normally.

When the unit receives the start signal, it restarts at the last set-
tings set.
For further information please contact the authorized service center.
Multifunction board
Terminal board
Indoor unit display board
ON/OFF Remote "1": connect ON-OFF1 and ON-OFF2
ON/OFF Remote "2" connect SWITCH1 and SWITCH2
Jumper inserted
Remove Jumper