ASG BLG-5000 Series Podręcznik operacyjny - Strona 11

Przeglądaj online lub pobierz pdf Podręcznik operacyjny dla Wkrętak sieciowy ASG BLG-5000 Series. ASG BLG-5000 Series 17 stron. With built in screw counter, with built in screw counter and pulse system, for use with screw counter
Również dla ASG BLG-5000 Series: Podręcznik operacyjny (7 strony)

■ Output messages
Receiving Inquiry Command: The message No. 1 to 16 will be responded only when Inquiry Command is
received. The other messages will be responded during operations such as screw tightening.
No.
Function
1
All functions availability
2
Cycle count
3
Min. Motor Revolutions
4
Max. Motor Revolutions
5
Work Reset Timer
6
Reverse Count Timer
7
System
8
Over Time - Short Time
9
Panel Buttons availability
10
No error time for double fastening
11
Version
12
Total number of the driver shut off (Torque Up)
13
Message for receipt of abnormal messages
14
Lever Control availability
15
Emergency Stop
16
Detecting presence of work parts
17
Lever Switch
18
Driver shut off (Torque Up)
19
Message for no errors in screw tightening
20
Pass Judgment
21
Message for errors in screw tightening
22
Fail Judgment
23
Message for loosening screws
24
Message for Count Reset
25
Message for limitation in use
26
Message for error in presence of a work part
27
Unlocking screwdriver
■ How to unlock the screwdriver blinking the mark"-"
If the total number of the driver shut off (Torque Up) has reached to one million times, the mark "—" starts
blinking on the display of the unit. This means maintenance and calibration are needed.
To stop the mark "-" blinking, choose an either way described below:
1. By using the buttons on the unit ⇒ Press and hold the F2 and F3 button at the same time.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
HIOS BLG Series: BLG-BC2
Operational Manual
Response
Message
AP:0 /AP:1
Ao:0 / Ao:1
Ver x.xx
yyyy/MM/dd
CE: Received
message
Lv:0 / Lv:1
Em:0 / Em:1
W:0 / W:1
L:0 / L:1
D: No. of screws,
Operation time
E: Operation
time
R: No. of screws,
Operation time
W: Err
3/5
| Phone: (
44110-3898
888) 486-6163
Remarks
0: available
1: unavailable
An: x
x : setup value
Ac: x
AC: x
At: x
Ar: x
Ad: x
AU: x
AG: x
x.xx : version number
yyyy/MM/dd date
AL: x
x: Total number of the driver shut off
regardless of whether the BC2
functions are ON/OFF.
Message when received message is
abnormal.
Lv:0 available
Lv:1 unavailable
Em:0 OFF
Em:1 ON
W:0 without work parts
W:1 with work parts
L:0 On / L:1 Off
T
Message when screw tightening is
done properly.
PASS
If the operation time exceeds 10s, it is
displayed as "****".
FAIL
Message when screw loosening is
done properly.
R
Over
Message when total number of the
driver shut off has reached 1 million
times
when a work part is removed before
completion of screw tightening
SL
Unlocking the screwdriver blinking
the mark " – " .
BC2 Communication 1510-E HIOS Inc.
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
216) 481-4519