4.4 IR Function Chart
IR OUT A
IR IN 1
IR IN 2
IR IN 3
IR IN 4
IR IN 5
IR Sensor
◎: IR in can select IR out
✕: Only accepts an IR signal from the unit's remote control (included in the
package).
△: You do not have to select IR input as this device can receive IR signals
from all IR remote controls with a frequency between 30KHz~50 KHz
▲: You do not have to select input IR as this device can send IR signals to
all sources with a frequency between 30KHz~50 KHz
4.5 IR Cable Pin Definitions
IR Receiver
① IR signal
② Power 5V
③ Grounding
① ② ③
Note: Both the IR Receiver & Blaster can support a frequency of
30~50KHz.
IR OUT B
◎
◎
◎
◎
◎
◎
◎
◎
△
△
IR OUT C
◎
◎
◎
◎
△
X
IR Blaster
① Power 5V
② IR Blaster Signal
③ NC
① ②
③
Page 5
IR OUT D
IR OUT E
◎
◎
◎
◎
△
△ ▲
▲
▲
▲
▲