CYP OR-IR44 Instrukcja obsługi - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przełącznik matrycowy CYP OR-IR44. CYP OR-IR44 12 stron. Cyp or-ir44 infrared 4 x 4 matrix

CYP OR-IR44 Instrukcja obsługi

4.4 IR Function Chart

IR OUT A
IR IN 1
IR IN 2
IR IN 3
IR IN 4
IR IN 5
IR Sensor
◎: IR in can select IR out
✕: Only accepts an IR signal from the unit's remote control (included in the
package).
△: You do not have to select IR input as this device can receive IR signals
from all IR remote controls with a frequency between 30KHz~50 KHz
▲: You do not have to select input IR as this device can send IR signals to
all sources with a frequency between 30KHz~50 KHz

4.5 IR Cable Pin Definitions

IR Receiver
① IR signal
② Power 5V
③ Grounding
① ② ③
Note: Both the IR Receiver & Blaster can support a frequency of
30~50KHz.
IR OUT B
IR OUT C
X
IR Blaster
① Power 5V
② IR Blaster Signal
③ NC
① ②
Page 5
IR OUT D
IR OUT E
△ ▲