Figure 4
The elevation stop position and their corresponding stop/plug configurations are shown in the
table below. The hole location for the plug/stop is referred to by an angle from the horizontal.
The outlet angle is the angle trajectory (from horizontal) the water will flow from the
StreamMaster unit.
Note that the permanent stop must remain installed. If this stop is removed, the outlet will go past vertical and the gear will run out
of travel.
There are six options for the customer to use. This is achieved with 3 plugs, 1 permanent stop, and 2 stops provided (the unit
will be assembled with the permanent stop in 0˚ location, 1 stop in the -45˚, and plugs in the remaining 15˚ and -60˚ locations).
The parts kit will contain 1 stop and 1 plug.
P
PS
S
ELEVATION STOPS
HOLE LOCATION
15˚
-45˚
P
PS
S
P
PS
P
S
PS
P
P
PS
P
S
PS
P
S
PS
S
P=PLUG S=STOP PS=PERMANENT STOP
Factory Set Stops
15°
-45°
-60°
P
LOWER
OUTLET
ANGLE
-60˚
P
-45˚
S
-45˚
P
-30˚
P
-45˚
S
-30˚
P
-30˚
Page 13
UPPER
OUTLET
ANGLE
45˚
30˚
90˚
90˚
30˚
45˚