Acquaer TRP010-2 Instrukcja obsługi - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Acquaer TRP010-2. Acquaer TRP010-2 13 stron. Transfer pump

Acquaer TRP010-2 Instrukcja obsługi
Model: TRP010-2
Property
Voltage
Horse Power
Amps
Max. Head (ft.)
Max. Flow (GPH)
Discharge Size (in.)
Power cord length (ft.)
Model
TRP010-2
WARNING
This pump is not submersible! Do not stand in water while this pump is plugged in, and do not get the
motor wet as it could cause electrocution, which could lead to serious injury or death.
Always make sure the pump is unplugged as soon as the water level reaches 1/8 in. At water levels
less than 1/8 in., the pump is attempting to pump air, which will cause the pump to overheat and wear
out. Running the pump without sufficient water will damage the pump and void the pump's warranty.
When the pump is running dry, it will be EXTREMELY LOUD. This is a sign to unplug the pump.
You must use the included clear suction hose on the inlet of this pump, as marked on the pump.
Always use the suction strainer included with this pump to prevent debris from damaging the pump.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in
the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can
cause an explosion or fire, resulting in property damage, serious personal injury and/or death.
Always disconnect the pump from its power source before inspection.
Do not stand in water when the pump is connected. Do not handle pump with wet hands.
Do not touch the pump housing while it is operating, as the pump may be HOT and can cause serious
skin burns.

TECHNICAL SPECIFICATIONS

PERFORMANCE
GPH of water @ Total Ft. Head
0 ft.
10 ft.
264
242

SAFETY INFORMATION

Specifications
115V/60Hz
20 ft.
30 ft.
195
132
1/10HP
1.8A
46 ft.
264
3/4 in.
6 ft.
Max.
Head
40 ft.
46ft
60