Ashcroft k1 Arkusz instrukcji - Strona 2
Przeglądaj online lub pobierz pdf Arkusz instrukcji dla Przetwornik Ashcroft k1. Ashcroft k1 2 stron. Pressure transducer
K1, K2, K8
PRESSURE TRANSDUCER
INSTRUCTION SHEET
Wiring Diagrams for All Transducers
+
RED
(+ Power)
POWER
WHITE
(- Power)
SUPPLY
–
+
GREEN
(+ Output)
BLACK
(- Output)
–
(Blue, K8 only)
METER
4-Wire Ratiometric (mV/V)
+
(+ Power)
POWER
(Common)
SUPPLY
–
–
(+ Output)
+
METER
3-Wire Voltage
POWER
SUPPLY
+
–
(+)
POWER
TRANSDUCER
(–)
OUTPUT
+
–
METER
4-20 mA
K1 Transducers – Electrical Connections
Voltage Output Units 1-5, 1-6 Vdc
CONNECTOR
TYPE
Hirschmann Type
PIN 1
=
+ Power
PIN 2
=
Common
PIN 4
=
Output
Bendix 4-Pin, 6-Pin
Pin A
=
+ Power
Pin B
=
Output
Pin D
=
Common
Cable Type F2
Red
=
+ Power
White
=
Common
Green
=
Output
Cable Type C1
Red
= + Power
White
=
Common
Green
=
Output
Current Output Units 4-20mA
CONNECTOR
TYPE
Cable Type F2
Red
=
+ Power
Black
=
– Power
Cable Type C1
Red
=
+ Power
Black
=
– Power
Hirschmann Type
Pin-1
=
+ Power
Pin-2
=
– Power
Bendix 4-Pin, 6-Pin
Pin A
=
+ Power
Pin B
=
– Power
© 2012 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614, USA. Tel: 203-378-8281 • Fax: 203-378-0499, All specifications are subject to change without notice.
All sales subject to standard terms and conditions. All rights reserved. www.ashcroft.com. I&M011-10063-1/01 (250-2924). Rev. A 7/12
Dimensions
NOTE: All dimensions are decimal inches
K1, K2 Transducers
TRANSDUCER
TRANSDUCER
MATING
K2 Transducers – Electrical Connections
CONNECTOR
CABLE CODING
Red
Black
Green
Red
Green
White
N/A
N/A
MATING
CONNECTOR
CABLE CODING
N/A
N/A
Recalibration Instructions:
1.
Apply 0% Full Scale Pressure.
2.
Set the output using the Zero adjustment potentiometer.
Red
3.
Apply 100% Full Scale Pressure.
Black
4.
Set the output using the Span adjustment potentiometer.
5.
Repeat steps 1 thru 4 as necessary.
Red
Green
6-PIN BENDIX
0.9 SQ.
-------------------
4-PIN BENDIX
0.8 SQ.
3.0
3.0
.625
HEX
Ratiometric (mV/V)
MATING
CONNECTOR
CONNECTOR
TYPE
CABLE CODING
Cable Type F2
Red
=
+ Power
White
=
– Power
N/A
Green
=
+ Output
Black
=
– Output
Cable Type C1
Red
= + Power
White
= – Power
N/A
Green
= + Output
Black
= – Output
Bendix 4-Pin
Pin A
=
+Power
Red
Pin B
=
+Output
Green
Pin C
=
– Output
Black
Pin D
=
– Power
White
Bendix 6-Pin
Pin A
=
+Power
Red
Pin D
=
– Power
White
Pin B
=
+Output
Green
Pin C
=
– Output
Black
Pin E
=
Shunt Cal.
Pin F
=
Shunt Cal.
K8 Transducers
0.5
0.5
0.34
1.1
K8 Transducers – Electrical Connections
Ratiometric (mV/V)
Cable Type F2
Red
=
+ Power
White
=
– Power
Green
=
+ Output
Black
=
– Output
4 Inch Leads
Red*
=
+ Power
White
=
– Power
Green
=
+ Output
Blue
=
– Output
*Orange
=
+ Power, RoHS compliant
versions
Special Wiring – See "X" Variation
On Unit Label
Variation
Wire Hookup
Red
=
+ Power
XTQ
Black
=
Common
White
=
Output
Red
=
+ Power
XTG
Black
=
Common
Green
=
Output
2.1
.625
HEX