DOLD BH 5911 Instrukcja obsługi - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Jednostka sterująca DOLD BH 5911. DOLD BH 5911 20 stron. Multi-function safety system safemaster m control unit

DOLD BH 5911 Instrukcja obsługi
Technical Data
General Data
Operatinng mode:
Temperature range:
Clearance and creepage
distances
rated impuls voltage /
pollution degree:
EMC:
Radio interference
suppression:
Remark: This device is designed for industrial ambient conditions.
When used in other environment, it is possible that wire bound or
radiated interference occurs.
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Shock resistance:
Acceleration:
Pulse duration:
Number of shocks:
Climate resistance:
Terminal designation:
Wire connections:
Wire fixing:
Surge supression:
Mounting:
Dimensions
Width x height x depth:
CSA-Data
Wire connection:
Technical data that is not stated in the CSA-Data, can be found
in the technical data section.
nfo
CCC-Data
Thermal current I
:
th
Switching capacity
to AC 15:
to DC 13:
Technical data that is not stated in the CCC-Data, can be found
in the technical data section.
nfo
Ordering Example
BH 5911.03/00MF0 DC24V
BH 5911.22/00MF0 DC24V
Continuous
± 0 ... + 50 °C
At an operating temperature of 50 °C
the modules must be mounted with
a distance of 3 - 5 mm.
4 kV / 2 (basis insulation) IEC 60 664-1
IEC/EN 61 326-3-1, IEC/EN 62 061
Limit value class A
EN 55 011
IP 20
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplast with V0 behavior
according to UL Subject 94
Amplitude 0.35 mm
Frequency 10 ... 55 Hz, IEC/EN 60 068-2-6
10 g
16 ms
1000 per axis on three axes
0 / 050 / 04
IEC/EN 60 068-1
EN 50 005
DIN 46 228-1/-2/-3/-4
Plus-minus terminal screws M3,5
box terminals with wire protection
When connecting inductive loads to the
relay outputs (contactor coils, valves,
electric brakes) surge supressor elements
like diods, capacitros, RC combinations,
etc. have to be connected directly to the
connection terminals of the controlled
devices, keeping the connection wires
as short as possible.
DIN rail
IEC/EN 60 715
45 x 84 x 121 mm
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
4 A
3 A / AC 230 V
IEC/EN 60 947-5-1
1 A / DC 24 V
IEC/EN 60 947-5-1
3 NO contacts
2 NO contacts, 1 NC contact
8
BH 5911 / 151007 / 478