Technical Data
Input
Nominal voltage A1/A2 U
:
N
Voltage range:
Nominal consumption:
Operating distance
S
:
on
S
:
off
undefined situation:
Max. mounting difference:
San
sensor
actuator
M8351_a
Output
NE 5020.92
Output 14:
Output 24:
Reaction time:
Thermal current I
:
th
Electrical life:
Permissible switching
frequency:
General Data
Operating mode:
Temperature range:
Operation:
Storage:
Altitude:
Strain relieve:
EMC
Electrostatic discharge:
HF-irradiation:
Fast transients:
Surge voltages
between
wires for power supply:
between wire and ground:
HF-wire guided:
Interference suppression:
Degree of protection
Housing:
Housing:
Vibration resistance:
Climate resistance:
Wire connection:
Length of cable:
Mounting:
Mounting torque:
Weight:
Transmitter:
Receiver:
Dimensions
Width x height x depth:
Transmitter:
Receiver:
E. DOLD & SÖHNE KG • D-78114 Furtwangen
e-mail: [email protected] • internet: http://www.dold.com
DC 24 V
0.9 ... 1.1 U
N
27 mA
≤ 5.5 mm
≥ 13 mm
5.6 ... 12.9 mm
y = ± 1 mm
Sab
sensor
actuator
2 semiconductor outputs
+ DC 24 V (+ switching)
0V (- switching)
max. 50 ms
max. 200 mA
50 x 10
switching cycles
6
3 600 switching cycles / h
Continuous operation
- 25 ... + 60 °C
- 25 ... + 60 °C
< 2,000 m
VDE 0623, IEC/EN 60 669-1 (appendix B)
8 kV (air)
IEC/EN 61 000-4-2
10 V/m
IEC/EN 61 000-4-3
4 kV
IEC/EN 61 000-4-4
0.5 kV
IEC/EN 61 000-4-5
4 kV
IEC/EN 61 000-4-5
10 V
IeC/EN 61 000-4-6
Limit value class B
EN 55 011
IP 67
IEC/EN 60 529
Thermoplast with V0-behaviour
according to UL subject 94
Amplitude 0.35 mm IEC/EN 60 068-2-6
frequency 10 ... 55 Hz
25 / 060 / 04
IEC/EN 60 068-1
4 wires with open end
white: + 24 V
green:
0 V
brown: +24 V switched signal
yellow:
0 V switched signal
or M8/M12-connector, pin configuration
see drawing
4 m, according to UL Style 2464
Screw M4
with plain washer
EN ISO 7092
max. 1.1 Nm
45 g
95 g
92 x 24 x 18 mm
92 x 24 x 23.5 mm
Connection
Connection
A1
A2
14
24
Standard Type
NE 5020.92 DC 24V
Article number:
• Output:
• Nominal voltage U
:
N
• Connection cable:
Ordering Example
NE 5020
.92
/_ _ _ /_ _ _ _
Troubleshooting
Failure
LED OFF
Maintenance and repairs
- The device contains no parts that require maintenance.
- In case of failure, do not open the device but send it to manufacturer
for repair.
PO Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356
12
Signal designation
Auxiliary voltage DC 24V
Auxiliary voltage 0 V
Semiconductor outputs
plus 24 V switching
Semiconductor outputs
0 V switching
0051641 (for Receiver and Transmitter)
2 semiconductor outputs
DC 24 V
4 m, open wire
DC 24 V
Nominal voltage
Coded, safe against
manipulation
0011
0110
1001
1100
Connection cable
0: Standard
1: Connection cable with
M12 connector
(on request)
2: Connection cable with
M8 connector
(on request)
Switching distance
0: S
= 5.5 mm; S
an
ab
1: S
=
4 mm; S
an
ab
Cable length
0:
300 mm
1: 1000 mm
Q: 100 mm
Output
Type
Potential cause
- Supply voltage is not present
- Distance between transmitter and
receiver to large
NE 5020 / 23.07.18 en / 004A
= 13 mm
= 10 mm