APPLIANCE DATA
2.0
Gas Group
Inlet/Operating Pressure
Regulator Pressure
Max Energy Input (Gross)
Max Energy Input (Net)
Max Gas Rate
Min Energy Input (Gross)
Min Energy Input (Net)
Pilot Energy Input (Gross)
Pilot Energy Input (Net)
Flow restrictor orifice
Injector
Oxypilot
Gas control
Gas Inlet restrictor elbow
Ignition
Spark Gap (± 1.0mm)
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.
3.0
INSTALLATION REQUIREMENTS
If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue
then the old flue must be sealed off. It will be necessary to ventilate the old flue to prevent condensa-
tion and dampness forming, however any air vent used to ventilate the old flue must not be sited with-
in 500mm of this appliance. If the flue can be ventilated to the outside of the building then this is usu-
ally the best solution. If in doubt then advice should be sought from a local building control officer. The
appliance is designed to be wall mounted. If the appliance is to be mounted on a newly fabricated area
of wall that also serves the purpose of sealing off the old flue then it is very important that there are
no holes, gaps or otherwise in this wall that will allow draughts from the old flue to enter the room,
especially directly behind the appliance. Such draughts could affect the performance of the ODS sys-
tem and result in nuisance cutting out, for example. If the gas supply pipe is to enter the appliance
from the rear, i.e. emerge from the wall behind the appliance, then any hole in the wall from which the
pipe emerges must be tightly sealed.Propane/LPG models must not be installed in cellars, basements or
any room which is completely below ground level.
3.1
ROOM SIZING
All Models : The room size should be a minimum of 23m
circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces
but these spaces must not be separated by a door. To calculate a room size in cubic metres (m
the room volume in cubic feet (ft
4.0
SITE REQUIREMENTS
This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall.
This appliance may be installed in any room in the home except bathrooms. If the appliance is to be
fitted in a bedroom then an electronic carbon monoxide detector complying with the current edition of
BSEN 50291 must be installed in the same room as the appliance. For maximum safety it is recom-
mended that such device is continuously (mains) powered and arranged in such a way that the gas sup-
ply to the appliance is isolated in the event of an alarm. The selection and installation of such device
shall be in accordance with the current edition of BSEN 50292, and the user must be briefed regarding
the use and maintenance of such a device. Installation in living rooms is common, however other rooms
such as kitchens, dining rooms and hallways are permitted, providing a suitable gas supply is available,
and rooms sizing and ventilation requirements are strictly adhered to (see sections 3.1 and 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal
gentle draughts experienced within the home. It is not recommended, however that the appliance be
installed in areas where it is likely to be directly exposed to persistent strong draughts, that may be
generated by outside doors, windows, air vents, air conditioning units, extractor fans, ceiling fans etc.
See section 4.1 for more information on ventilation.
600 Natural gas
600 LPG
G20 Natural Gas CAT I2H
G31 Propane CAT I3P
20 mbar (± 2.0mbar)
37 mbar (± 2.0mbar)
N/A
24.5 mbar
2.0 kW
1.7 kW
1.8 kW
1.56 kW
0.20 m 3 /h
0.065 m 3 /h
1.0 kW
1.0 kW
0.9 kW
0.91 kW
166 W
166 W
150 W
152 W
1.00 mm
0.65 mm
N/A
1.30 mm (single)
SIT 9082
Seagas P5-19/SIT 9286
Copreci 21400
Copreci 21400
8mm
8mm
Double piezo spark
Double piezo spark
3.5 - 4.5mm
3.5 - 4.5mm
3
) by 35.3.
750 Natural gas
G20 Natural Gas CAT I2H
20 mbar (± 2.0mbar)
N/A
2.0 kW
1.8 kW
0.20 m 3 /h
1.3 kW
1.17 kW
166 W
150 W
1.00 mm
N/A
SIT 9082
Copreci 21400
8mm
Double piezo spark
3.5 - 4.5mm
3
(e.g. 10'1" x 10'1" x 8') to allow adequate
2
750 LPG
G31 Propane CAT I3P
37 mbar (± 2.0mbar)
24.5 mbar
1.7 kW
1.56 kW
0.065 m 3 /h
1.3 kW
1.2 kW
166 W
152 W
0.65 mm
1.30 mm (single)
Seagas P5-19/SIT 9286
Copreci 21400
8mm
Double piezo spark
3.5 - 4.5mm
3
) divide
©