Cloud BT-IEW Instrukcja instalacji - Strona 15

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Jednostka sterująca Cloud BT-IEW. Cloud BT-IEW 16 stron. Bt-i series bluetooth wireless audio module

Non-secured mode:
In Non-secured mode, it is not necessary to initiate a connection with the PUSH-TO-PAIR button. The BT-1 will "pair"
with the first device that requests pairing. Once pairing is established, no other device can connect to it, in the same way
as in Secured mode.
Streaming may now commence: on receipt of audio data, the STATUS LED turns blue.
Disconnection may be achieved by any of the three methods outlined above for "Secured" mode.

Power considerations

The BT-1 will operate from a DC power supply in the range 12 V to 24 V. This will be supplied by the host unit's Facility Port
or Extension Port via the Cat 5 connection: Cloud Z4/Z8
Z4/Z8
and 46-120 host units supply +/-12 V. The DCM1 range supply +/- 12 V from their Extension Ports.
MK4
The BT-1 consumes 20 to 26 mA from the host unit's power supply. In the majority of installations, the host unit will have ample
spare current capacity to power one or more BT-1s. However, installers should note that this may not be the case in a very large
system with multiple remote modules in several Zones. If there is any doubt about the power capability, please refer to the host
unit's Installation and User Guide where full details of power supply ratings can be found.
Should you have any questions concerning the installation and connection of the Cloud BT-1, please visit
www.cloud.co.uk/resources, where you will find additional technical information.
host units supply +/- 15 V from their Facility Ports while the
MK3
BT-1 Installation Guide v1.0
15