Cypress OSM-1000-BRD Skrócona instrukcja obsługi
Wiegand
Access
Control Panel
Ground
Data 0
Data 1
LED Out
Beeper Out
12VDC
Power
Supply
Power
Ground
Wiegand
Card
Reader
Power
Ground
Data 0
Data 1
LED IN
Status LED Behavior:
The OSM-1000-BRD unit has a tri-color LED that can display red, green, blue, and white. The startup sequence lasts
approximately 5 seconds and the LED will display red, blue, green, white or display red, green, blue, white.
ACU Mode:
OSM-1000 is communicating with PD: the status LED will be blue with green flashes or green with blue flashes. The
status LED will briefly turn red when it receives reader data from the PD.
OSM-1000 is not communicating with PD: the status LED will be blue with slow, green flashes or green with slow,
blue flashes.
PD Mode:
OSM-1000 is communicating with ACU: the status LED will be red with blue flashes or red with green flashes.
OSM-1000 has not been polled by the ACU: the status LED will slowly fade from green to off, and back to green.
ACU stops communicating with OSM-1000: the status LED will slowly fade from red to off, and back to red.
Bench Testing:
Bench testing is recommended to avoid troubleshooting issues in the field.
ACU Mode:
1. At the bench, connect the OSM unit to the PD and the Wiegand access controller by following the ACU Mode
Wiring Diagram.
2. Observe the OSM unit and PD communicating. Refer to the "Status LED Behavior" section to verify that the OSM
unit is communicating with the PD.
3. If the devices do not communicate, make sure the the baud rate and polling ID match. In the OSDP spec, the
default baud rate is 9600 and the default polling ID is 0.
PD Mode:
1. At the bench, connect the OSM unit to the Wiegand reader and ACU by following the PD Mode Wiring Diagram.
2. Observe the OSM unit and ACU communicating. Refer to the "Status LED Behavior" section to verify that the OSM
unit is communicating with the ACU.
3. If the devices do not communicate, make sure the the baud rate and polling ID match. In the OSDP spec, the
default baud rate is 9600 and the default polling ID is 0.
ACU Mode Wiring Diagram
12VDC
Power
Supply
Power
Ground
8 - 16 VDC Input
Ground
Data 0
Data 1
LED I/O
Ground
Input 1
Input 0
PD Mode Wiring Diagram
8 - 16 VDC Input
Ground
Data 0
Data 1
LED I/O
Ground
Input 1
Input 0
12VDC
Power
Supply
Power
Ground
RS485 -
RS485 +
Ground
Strike N.O.
Strike COM
Strike N.C.
Ground
8 - 16 VDC Input
RS485 -
RS485 +
Ground
Strike N.O.
Strike COM
Strike N.C.
Ground
8 - 16 VDC Input
OSDP
Card
Reader
Power
Ground
RS485 -
RS485 +
OSDP Access
Control Panel
RS485 -
RS485 +