Cypress DPX-5510 Instrukcja obsługi - Strona 15

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przedłużacz Cypress DPX-5510. Cypress DPX-5510 15 stron. Wireless reader extenders

The Green power LED should always be illuminated if power is applied. If this LED is not illuminated
there is a power problem, or a problem with the unit.
It is a good idea to switch both Central and Remote units to Service / Config mode to verify the field
installation.
Both units should be communicating. See bench test sequence for details for LED indicators when in
Service / Config mode.
Check operation of Badge reader, LED and other I/O that is used in the installation while in Service /
Config mode.
Once operation has been verified in Service / Config mode then the units can be placed in Normal Run
mode. The Amber com LED will flash infrequently in Normal mode. It should flash each time a badge is
swiped or any of the I/O changes status.
The Central unit diagnostic LED will be Red when the units are not communicating. This may be
happen when the Central unit powers up without the Remote unit having power. Once both units are
powered up the diagnostic LEDs should both enter a flashing green on and off mode. This should
occur within 30 seconds of both units having power applied in Normal mode.
Check operation of Badge reader, LED and other I/O in Normal mode.
©2008 Cypress Computer Systems,Inc. • www.cypressworld.com 3/4/08

Final Checkout

Insert cover mounting screws and tighten.
Installation is complete.
Page 15