Cypress Suprex SPX-5600 Series Instrukcja obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przedłużacz Cypress Suprex SPX-5600 Series. Cypress Suprex SPX-5600 Series 20 stron. Reader extender - rf wireless interface

Note: The LED and Door Strike operation of the RF Suprex differs from previous Suprex versions.
To activate the relay on the Remote unit, connect as shown below. These connections can be used
to allow the Remote relay to operate a DOOR STRIKE, GATE, or other locking hardware. Refer to
following pages in this document for details of each I/O operation and connection.
There are two relays available for accessory outputs at the Remote end. Either relay can be used
to provide the Door Strike or Gate activation function. This example uses Relay 1.
Only Relay and LED Connections are shown for clarity, refer to previous diagrams for Power and Data connections.
Page 10 of 20
Cypress Suprex RF Series - Door Strike and LED I/O
Wiring Example - Door Strike Follows LED
Access
Control
Panel
Wiring Example - Door Strike does not follow LED
Access
Control
Panel
Ground
LED Signal
Ground
LED Signal
Strike Signal
Ground
Suprex RF Central
R1 Input
Controls
Strike on
Remote
LED In
R1 IN
Ground
Suprex RF Central
R1 Input
Controls
Strike on
Remote
LED In
R1 IN