Cytech KP04 Skrócona instrukcja obsługi - Strona 2

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Keypad Cytech KP04. Cytech KP04 4 stron. Lcd keypad
Również dla Cytech KP04: Instrukcja instalacji (20 strony)

announcements. KP04 and KP05 have the same
functions and specifications, except that KP04 is
mounted vertically (see above figure) and KP05 is
horizontal
Specifications
Dim: 89 x 160 x 31 mm. Carton 92 x 165 x 45 mm
Weight: 177 g
2 lines by 16 character LCD
Power Supply: 12V DC from Comfort System
Current Consumption: 50 mA idle (No voice)
Comfort IR codes received: RC01 codes
Speaker for announcement, intercom , messages.
Microphone for recording and Intercom
System Requirements
Comfort II Controller
Contents
KP04 or KP05 keypad
2 wall plugs and screws for mounting.
3 x 2 way removable terminal blocks
Connections to Comfort
JP1 – 12V/COM Connected to 12V/COM (Comfort)
JP2 – KA/KB. Connected to KA/KB (Comfort.)
JP3 – VOICE/MIC Connected to KP VOICE/MIC
(Comfort)
Cables
Shielded twisted 4-pair cable advisedfor wiring between
Comfort and keypads to avoid interference from mains
wiring and electrical appliances to Microphone signals.
Jumper Settings
JP4 – 3 pin header for Backlight . "Normal"
(default) for backlight on when key is pressed,
Entry Alert or Alarm. "On" position switches
Backlight permanently on.
JP6 – Keypad Key Beep volume. Open for softer
beep volume. It is shunted by default (i.e. loud).
JP7 – Tamper Shunt. Shunted to disable tamper
switch (Default), open to enable Tamper switch.