BluePoint Fasteners BP-361N Instrukcja obsługi - Strona 15
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Elektronarzędzie BluePoint Fasteners BP-361N. BluePoint Fasteners BP-361N 18 stron.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
•
Cartridge does
Tool damaged
•
not advance
Cartridge strip
damaged
•
Carbon build-up
•
Cartridge strip
Tool overheated
cannot be
because of high
removed
firing rate
•
Tool damaged
WARNING
Never attempt to pry a
cartridge from the
magazine strip or tool
•
Cartridge cannot
Bad cartridge
•
be fired
Carbon build-up
WARNING
Never attempt to pry a
cartridge from the
magazine strip or tool
•
Cartridge strip
Tool is compressed
melts
too long while
fastening.
•
Fastening
frequency is too
high
•
Cartridge falls
Fastening
out of the
frequency is too
cartridge strip
high
WARNING
Never attempt to pry a
cartridge from the
magazine strip or tool
POSSIBLE REMEDIES
•
Clean the cartridge strip
guideway
•
Change the cartridge strip
If the problem continues:
•
Contact Bluepoint
•
Let the tool cool down and
then carefully try to
remove the cartridge strip
If the problem continues:
•
Contact Bluepoint
•
Manually advance the
cartridge strip by one
cartridge
•
If the problem occurs
more often: Clean the tool
If the problem continues:
•
Contact Bluepoint
•
Compress the tool only
while fastening.
•
Remove the cartridge strip
•
Disassemble the tool for
fast cooling and to avoid
possible damage
•
Do not exceed
recommended driving rate
•
Use only Bluepoint strip
loads
If the tool cannot be
dismantled:
•
Contact Bluepoint
•
Discontinue using the tool
immediately and let it cool
down
•
Remove the cartridge strip
•
Clean the tool and remove
the loose cartridge
If the tool cannot be
disassembled:
•
Contact Bluepoint
28
TROUBLESHOOTING
FAULT
CAUSE
•
The operator
Carbon build-up
notices:
– increase in
contact pressure
– increase in trigger
force
– power regulation
too stiff to adjust
– cartridge strip is
difficult to remove
•
Varying depths
The tool is dirty
of penetration
(carbon build-up)
•
Variance in base
material hardness
•
Trigger cannot
Tool not fully
be pulled
compressed
•
Safety mechanism
activated because:
o Magazine not
loaded
o Plastic debris
inside the
magazine
o Incorrect piston
position
o Nail incorrectly
positioned in
magazine
•
Piston stuck in
Piston may be
magazine
damaged
•
fastener guide
Plastic debris may
be inside the
magazine
•
Excess power when
fastening on steel
•
Tool fired with high
power without
fastener in place
•
Fastener
Fastener too short
•
penetrates too
Driving power too
deeply
high
POSSIBLE REMEDIES
•
Clean the tool
•
Ensure that the correct
and Bluepoint cartridges
are used.
•
Clean the tool
•
Check the piston, replace
if necessary
•
Release the tool and fully
compress it again
•
Load fastener strip
•
Open magazine, remove
fastener strip and plastic
debris
If problem continues:
•
Clean the tool
•
Check to ensure that the
tool is assembled
correctly
•
Unscrew the magazine
•
Unscrew the black part of
the housing
•
Check piston and replace
if necessary
•
Open magazine, remove
fastener strip and plastic
debris
•
Reduce the power setting
•
Avoid firing the tool
without a fastener in place
•
Use longer fastener
•
Reduce power setting
•
Use lighter cartridge
29