BluePoint Fasteners BP-361N Instrukcja obsługi - Strona 15

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Elektronarzędzie BluePoint Fasteners BP-361N. BluePoint Fasteners BP-361N 18 stron.

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
Cartridge does
Tool damaged
not advance
Cartridge strip
damaged
Carbon build-up
Cartridge strip
Tool overheated
cannot be
because of high
removed
firing rate
Tool damaged
WARNING
Never attempt to pry a
cartridge from the
magazine strip or tool
Cartridge cannot
Bad cartridge
be fired
Carbon build-up
WARNING
Never attempt to pry a
cartridge from the
magazine strip or tool
Cartridge strip
Tool is compressed
melts
too long while
fastening.
Fastening
frequency is too
high
Cartridge falls
Fastening
out of the
frequency is too
cartridge strip
high
WARNING
Never attempt to pry a
cartridge from the
magazine strip or tool
POSSIBLE REMEDIES
Clean the cartridge strip
guideway
Change the cartridge strip
If the problem continues:
Contact Bluepoint
Let the tool cool down and
then carefully try to
remove the cartridge strip
If the problem continues:
Contact Bluepoint
Manually advance the
cartridge strip by one
cartridge
If the problem occurs
more often: Clean the tool
If the problem continues:
Contact Bluepoint
Compress the tool only
while fastening.
Remove the cartridge strip
Disassemble the tool for
fast cooling and to avoid
possible damage
Do not exceed
recommended driving rate
Use only Bluepoint strip
loads
If the tool cannot be
dismantled:
Contact Bluepoint
Discontinue using the tool
immediately and let it cool
down
Remove the cartridge strip
Clean the tool and remove
the loose cartridge
If the tool cannot be
disassembled:
Contact Bluepoint
28
TROUBLESHOOTING
FAULT
CAUSE
The operator
Carbon build-up
notices:
– increase in
contact pressure
– increase in trigger
force
– power regulation
too stiff to adjust
– cartridge strip is
difficult to remove
Varying depths
The tool is dirty
of penetration
(carbon build-up)
Variance in base
material hardness
Trigger cannot
Tool not fully
be pulled
compressed
Safety mechanism
activated because:
o Magazine not
loaded
o Plastic debris
inside the
magazine
o Incorrect piston
position
o Nail incorrectly
positioned in
magazine
Piston stuck in
Piston may be
magazine
damaged
fastener guide
Plastic debris may
be inside the
magazine
Excess power when
fastening on steel
Tool fired with high
power without
fastener in place
Fastener
Fastener too short
penetrates too
Driving power too
deeply
high
POSSIBLE REMEDIES
Clean the tool
Ensure that the correct
and Bluepoint cartridges
are used.
Clean the tool
Check the piston, replace
if necessary
Release the tool and fully
compress it again
Load fastener strip
Open magazine, remove
fastener strip and plastic
debris
If problem continues:
Clean the tool
Check to ensure that the
tool is assembled
correctly
Unscrew the magazine
Unscrew the black part of
the housing
Check piston and replace
if necessary
Open magazine, remove
fastener strip and plastic
debris
Reduce the power setting
Avoid firing the tool
without a fastener in place
Use longer fastener
Reduce power setting
Use lighter cartridge
29