EG4 1570007 Podręcznik użytkownika - Strona 5
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Ładowarka EG4 1570007. EG4 1570007 6 stron. Ac charger 100a 48vdc
Warning: Ensure battery breakers and/or battery on/off switches are in the off position and
the charger is not plugged in while installing battery charging cables.
AC and DC Connections
• Connect battery cables to the battery terminals or bus bars using appropriate size bolts.
• Ensure charger cable ring terminals are attached to the battery terminals/bus bar of the
proper polarity and tightened to the proper torque specifications.
• For 240V usage, plug the charger into a 250V 30A twist lock receptacle with a dedicated
30A breaker.
• For 120V usage, plug the charger into a 125V 30A receptacle with a dedicated 30A
breaker.
An additional adapter cable (sold separately) will be required.
OPERATION
Power ON/OFF
1. Ensure that the battery cables are securely connected.
2. Plug the charger into an outlet of the proper voltage and amperage.
3. Turn on battery breakers and/or battery on/off switches.
4. Turn on the built-in battery breaker on the front of the unit.
5. The unit will begin charging and work normally if properly connected.
Note: If battery voltages are zero, complete step 2 (plugging in the unit) after step 4, to
ensure batteries do not go into fault mode.
Operation and Display Panel
The operation and display panel, shown in the chart below, is located on the front
panel of the AC charger. It includes two indicators, four function keys and an LCD
display, indicating the operating status and input/output power information of the unit.
LED Indicator
LED Indicator
POWER
CHG
Function Keys
Function Key
ESC
UP
DOWN
ENTER
Green
Solid On
Solid On
Green
Flashing
Description
To exit setting mode
To go to previous selection
To go to next selection
To confirm the selection in setting mode or enter setting mode
Messages
The unit is powered on
Battery is fully charged.
Battery is charging.
4