Preparing the Salt Water Solution

1. Make sure the AC power adapter is
unplugged.
2. Remove the top cover and CEF lid.
NOTE: Only use non-iodized salt with
the Sterilizer.
3. Make sure the CEF is securely in place.
Make sure the CEF lid is turned with the
AquaSolvo logo aligned with the control
panel the water tank.
4. Using the scoop supplied with the Sterilizer,
place 3 scoops of non-iodized salt on top
of the CEF lid as shown .
AQUASOLVO
LOGO SHOULD
BE ALIGNED
WITH CONTROL
PANEL
Figure 3. Mixing Salt Water Solution
7
NOTE: Hard water can shorten the life of
the Sterilizer. Water used should not have a
hardness greater than 100ppm.
5. Close the top cover.
6. Pour fresh tap water over the CEF lid
into the water tank until the water level
reaches the MAX line on the water tank
(2500ml/84.54oz.). Make sure all the salt is
washed off the CEF lid.
7. Plug in the AC power cord to the sterilizer.
PLACE SALT
ON THESE AREAS
POUR WATER
OVER THIS AREA
OF CEF LID
ADD WATER
UNTIL LEVEL
REACHES
MAX LINE

Operating Procedures

1. Press the Power ON/OFF button to turn
the Sterilizer on. The unit will play the
start up sound (do-re-mi) and all the
indicators on the control panel will turn
on for 3 seconds.
2. The Power ON/OFF button will be
illuminated white, indicating that the
sterilizer is in standby mode.
3. Press the power ON/OFF button again
to begin operation. The blue light in the
water tank will turn on, and the fan speed
will default to level 2 fan speed and the
HOCl disinfection indicator/button will
illuminate, indicating that the sterilizer is
disinfenting bacteria and viruses from the
air.
4. Press the fan speed button to toggle
the fan speed between sleep, 2, and 3
speeds. When sleep mode is selected,
fan speed is reduced and the blue light
inside the water tank will turn off.
5. Press the power ON/OFF button again to
turn the sterilizer OFF.
Timer Operation
Press the timer button to toggle through the
options (2H-4H-8H-None). Once selected, an
internal timer controls operation of the Sterilizer
for the selected duration. Once the timer expires,
the sterilizer shuts down and enters the standby
mode. NOTE: Do not use this option if you want
the sterilizer to run continuously.
Humidifier Operation
To use the sterilizer as a standard humidifier to
increas the humidity in the room:
1. Fill the water tank with clean tap water - DO
NOT add salt to the tank.
2. Press the HOCl disinfection indicator/button
to toggle the HOCl generator off. This will
stop the disinfection function.
CEF Replacement
The CEF should be replaced every six
months, or whenever indicated by the filter
replacement indicator on the control panel.
Unplug the power cord and remove the top
cover. The sterilizer will automatically shut
down.
1. Remove the CEF lid.
2. Unscrew the CEF from the tank and
discard.
NOTE: Handle the new CEF by the end
caps to avoid touching the CEF and
preventing possible contamination of the
filter element.
3. Remove the replacement CEF from
packaging and screw it into the bottom
of the water tank. Plug in the power
cord.
4. Turn on the Sterilizer and press and hold
HOCl air disinfection button for three
seconds to reset the filter life timer.
Note that If you replace the filter before
the accumulated life time is reached, the
filter life timer cannot be reset.
To purchase replacement filters, please
visit: www.DHLifelabs.com