INSTALLER INFORMATION

Installing the Additional Controls (Remote Control)
Motor Installation
This procedure is to be followed for the installation of the Motor Unit,
which must be fitted to use all remote control options, except the
Fully Electronic Ignition System which has the motor built in.
Remove the retaining screw, (Figure 1) and by using the blade of a
small screwdriver, pry off the cover (opposite end of the cover to the
screw) (Figure 2).
Fig 1
Turn the geared knob fully counter clockwise to the end stop position.
Place the motor unit into position as shown in Figure 3. The motor
should fit into location and sit in place with the gear mating with the
teeth of the geared knob.
Replace the Plastic cover and replace
the retaining screw (without the metal
sleeve around the screw), this retains
both the cover and the motor.
The Control valve is now ready to be
fitted with the simple up/down control
system.
Fig 3
Fig 2
20
USER INFORMATION
Seagas Manual Control
Igniting the Pilot Light
not light, repeated immediately.
Continue to keep the knob depressed for a further 10 seconds, after
the pilot has been lit.
Upon releasing the knob, the permanent pilot will remain lit, if not
return to off position and repeat.
If under any circumstances the electric spark fails, the pilot may be lit
manually by proceeding with the ignition sequence as previously
described, and after turning the control knob through the spark
position, the knob should be held in and the pilot lit with a match or
other lighter.
Running the appliance at high output
Ignite permanent pilot as shown in
"Igniting the pilot light".
Turn the control knob fully anti-
clockwise to the High setting.
The appliance is now burning at its
highest operating output.
Running the appliance at lower setting
Turn the Control knob slightly anti-
clockwise
towards
the
ignition
position
until
reaching
stop,
depress and hold for five seconds
(only pilot gas flows).
Whilst still depressed, turn further
in an anti-clockwise direction to
activate the piezo. If the pilot does
Ignite permanent pilot and run
appliance at "High" setting for a
minimum of 10 minutes as shown
previous.
13