Operating the diesel engine
1) Warm up the engine without load for 3 minutes. The generator has a Low
Warning System, and the Oil Alarm Lamp will be activated by low oil pressure
or engine oil shortage; the warning system will shut down the engine if the oil
pressure is too low.
2) Do not adjust the speed limit regulation bolt or the fuel adjustment bolt. These
bolts have been set by the factory; changing them will affect the properties of
the engine performance.
3) Check to see if there are abnormal noises and if the performance is good.
Check the color of the exhaust gases. If there are abnormal noises, poor
performance or dark exhaust gases, stop the engine and find the cause of the
problem, or contact your nearest dealer.