AMC iComC 2x20 Manual do utilizador - Página 9

Procurar online ou descarregar pdf Manual do utilizador para Amplificador AMC iComC 2x20. AMC iComC 2x20 12 páginas. Communication amplifier
Também para AMC iComC 2x20: Manual do utilizador (9 páginas)

AMC iComC 2x20 Manual do utilizador

RS-232 commands

Baud rate 9600,
8 data bits,
no parity,
1 stop bit,
no flow control.
Notes:
Amplifiers respond prompt: PA>
Symbols xx in the volume control row mean volume level. Volume level range is 0-63.
Example: RS232 command "Volume 15<CR>" sets volume level 15.
Symbol x in the "Source selector" row mean input number.
Example: RS232 command "Source 2<CR>" enables audio signal from input 2.
Symbol xx in the treble row mean treble level. Treble level range is from -7 to +7.
Example: RS232 command "Treble +3<CR>" sets treble level +3.
Example: RS232 command "Treble 0<CR> sets treble level to default.
Symbol xx in the treble row mean treble level. Treble level range is from -7 to +7. Default treble
level is 0.
Example: RS232 command "Treble +3<CR>" sets treble level +3.
Example: RS232 command "Treble 0<CR> sets treble level to default.
Symbol xx in the bass row mean bass level. Bass level range is from -7 to +7. Default bass level is 0.
Example: RS232 command "Bass +4<CR>" sets bass level +4.
Example: RS232 command "Bass 0<CR> sets bass level to default.
Symbol xx in the balance row mean balance level. Balance level range is from L9 to R9. Default level
is 0.
Example: RS232 command "Balance L5<CR>" sets balance to L5.
Example: RS232 command "Balance 0<CR> sets balance level to default.
Function
Show status
Power on
Power off
Power on/off
Mute on
Mute off
Mute on/off
Volume control
Source selector
Treble control
Bass control
Balance control
Save settings
Command
Now<CR>
Power On<CR>
Power Off<CR>
Power Toggle <CR>
Mute On<CR>
Mute Off<CR>
Mute Toggle<CR>
Volume xx<CR>
Source x<CR>
Treble xx<CR>
Bass xx <CR>
Balance xx<CR>
Save<CR>