SPECIFICHE TECNICHE / SPECIFICATIONS
Alimentazione / Input Voltage:
Consumo / Current Drain: (Alarm/Stand-By)
Tensione nominale / tipical voltage
Portata in lunghezza / Coverage: PIR /MIC
Portata in larghezza / Angle:
Piroelettrico / PIR:
Lente (fasci e livelli) / Lens:
Durata allarme / Alarm period:
Antiapertura / Anti-opening:
Antistrisciamento / Creep zone:
Contatto di allarme / Alarm Contact:
Contatto di tamper / Tamper switch:
Temperatura di esercizio / Operating Temperature:
Temperatura di stoccaggio / Storage Temperature:
RFI Protezione / Protection:
Led WALK TEST (MIC and PIR)
Cover / Housing:
Accessori / Accessories:
Dimensioni / Dimensions:
Tutti i ns. prodotti sono conformi ai requisiti richiesti dalla norma CEI 79-2 2°ed. 1998 + Ab 2000.
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema di allarme elet-
tronico affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.
Our products/systems comply with the essential requirements of EEC directives.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not
limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it is possible for the product/
system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk
that this happens.
www.amcelettronica.com
MOUSE GS - Rev. 1.0
4
9 to 15 V
(23 mA/19mA) @ 13.8V
13.8V
12 mt/ 7mt
90°
2 elementi / 2 elements
18 patterns on 3 levels
2 sec.
100 mA - 40 V - 2.5 -16 Ω
Max 40 mA - 30 Vdc
From -10 °C to + 55 °C
From -20 °C to +60 °C
30 V / m (80 /2000 MHz)*
ABS
Snodo orientabile / Swivel bracket /
Rotule orientable **
110 x 60 x 46 mm
installation instructions