INSTALLATION
STEP I
Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out
STEP 2
Install inlet A and discharge, B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an ible location. If mounting vertically,
WIRING
STEP I
Use 14 gauge stranded wire to 20', 12 gauge to 50',
from power source.
STEP 2
Use a 10-15 amp rated (lighted) on-off switch on the (+)
positive (red) motor lead.
motor up, attach motor mounts first then pump head
mounts, while supporting weight of pump.
STEP 5
Use 1/2" I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connectors.
STEP 6
Install a 1/2" in line strainer #01740-002 in accessible
location between shower drain pan and pump inlet. This
strainer or equivalent is required for pump warranty to be
valid.
STEP 3
Install 10 amp fuse protection on the positive lead for the
-143 model, use a 7 amp fuse for the -343 model.