FLOJET 4305-502 Manual de instruções - Página 2

Procurar online ou descarregar pdf Manual de instruções para Bomba de água FLOJET 4305-502. FLOJET 4305-502 4 páginas. “quad ii diaphragm” automatic water system pump

FLOJET 4305-502 Manual de instruções
Water
Tank
Do Not Plumb Autofill
to Pump Suction Line
INSTALLATION
STEP 1
Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out.
STEP 2
Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors
in place.
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
vertically, motor up, attach motor mounts first, then
pump head mounts, while supporting weight of pump.
D.C. WIRING
STEP 1
Use 14 gauge stranded wire to 20', 12 gauge to 50',
from power source.
STEP 2
Use a 10-15 amp rated on-off switch on the (+) positive
(red) motor lead.
Water
City Water
Heater
Inlet
Autofill Tank Valve,
Plumb to Tank
Flojet Inlet
Strainer
Red (+)
Fuse
Check
Valve
STEP 5
Use 1/2" I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connectors.
STEP 6
Install no less than 3/8" I.D. hose for feed lines to
fixtures. Use high pressure hose on all city water lines.
STEP 7
Install a Flojet strainer in an accessible Location (for
inspection and cleaning) between the tank and pump
inlet. This strainer or equivalent is required for pump
warranty to be valid.
NOTE: Small accumulator tank maybe used for
smoother flow.
Black (–)
Switch
STEP 3
Install 10-15 amp fuse protection on the positive lead for
the -500, -144 and -143 models, use a 7 amp fuse for the
- 503 and -343 and a 4 amp fuse for -501 and -443 models.
NOTE: The 115 and 230 Volt models may be plugged
directly into any ac outlet. A G.Fl. (ground fault interruption)
outlet and switched circuit is recommended.
C
A
B
(+)
(–)
Battery