TankValve,
INSTALLATION
STEP 1
Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out.
STEP 2
lnstall inlet A and discharge B port connectors. Firmly
p u s h s l i d e c l i p s C f o r w a r d t o l o c k p o r t c o n n e c t o r s
I n p l a c e ,
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. lf mounting
vertically, motor up, attach motor mounts first, then
pump head mounts, while supporting weight of pump.
STEP 5
Use 1/2" LD. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connectors.
STEP 6
Install no less than 3/8" LD. hose for feed lines to
fixtures. Use high pressure hose on all city water lines.
STEP 7
Install a Flojet strainer in an accessible Location (for
inspection and cleaning) between the tank and pump
inlet. This strainer or equivalent is required for pump
warranty to be valid.
NOTE: Small accumulator tank maybe used for
smoother flow
Battery
D.C. WRII{G
STEP 1
Use 14 gauge stranded wire 10 2O', 12 gauge to 50',
from power source.
STEP 2
Use a 10-15 amp rated on-off swilch on the (+) positive
(red) motor lead.
STEP 3
Install 10-15 amp fuse protection on the positive lead for
the -500, -144 and -143 models, use a 7 amp fuse for the
- 503 and -343 and a 4 amp fuse for -501 and -443 models.
NOTE: The 115 and 230 Volt models may be plugged
directly into any ac outlet. A G.Fl. (ground fault interruption)
outlet and switched circuit is recommended.