To use as a vent (for vertical applications or temporary venting)
pull up on hex plug until fi rst detent is reached (see Figure 5). This
is the vented position.
To use as a return-to-tank port, remove fl ush plug from hex and
install compatible return line. Torque return line to 15-20 ft. lbs.
[20-27 Nm] in hex plug.
CAUTION: Pump reservoir must be vented using one
of the two vent options. Failure to do so may cause
cavitation and pump damage.
5.5 Mounting Pump
15000: Pump can be mounted horizontally or vertically. If
mounted vertically, position pump with hydraulic outlet port(s)
facing down.
15000 and 15020: The four holes in the bottom of the
reservoir should be used for bolting through the mounting surface
into the reservoir. Use the #10 x 5/8" fasteners included with
pump, or allow no more than 3/4" [19 mm] thread engagement
into reservoir.
CAUTION: When mounting the pump in the vertical
position, the vent screw must remain closed.
15040: The U-shaped mounting rails on the bottom of the
reservoir have four .26 in. [6,6 mm] holes for mounting.
5.6 Oil Level
Always check oil level with all cylinders or tools in the fully
retracted position. If they are advanced when the pump is fi lled,
the reservoir will be over-fi lled when they are retracted.
Use the low-level sight glass on the end of the pump to check the
oil level. When the pump is mounted horizontally, the reservoir
is full when oil is at the bottom of the fi ll port. If oil is not visible,
then oil must be added. To add oil, remove Vent/Fill plug from
reservoir (See section 5.4b).
When the pump is mounted vertically, 15000 the oil level should
be checked periodically by removing the pump and placing it
on a horizontal surface.
NOTE: Prior to mounting the 15000 pump in the vertical position, oil
volume in the reservoir must be reduced to 127 in3 [2,1 L] prevent
leakage through the vent/fi ll plug. See the specifi cation table on page
2 for usable oil capacity in vertical position.
6.0 OPERATION
6.1 Oil Level
Check the oil level of pump and add oil if necessary (See
Installation section, step 5.6).
6.2 Venting Pump
Make sure the pump reservoir is vented (See Installation section,
step 5.4).
6.3 Treadle Operation
See fi gure 6.
a) To Advance Cylinder: Depress the "PRESSURE" end of treadle
and the pump will start to pump hydraulic oil to the system.
b) To Hold The Cylinder Position: The pump will stop and hold
pressure when the treadle is in the free/neutral position (treadle is
not depressed in either "PRESSURE" or "RELEASE" positions.)
c) To Retract Cylinder: Depress the "RELEASE" end of the treadle
to retract cylinder. To stop the cylinder from retracting, release
the treadle and return it to the hold position.
6.4 Priming
Priming of the hydraulic pump is normally not required. If the
air motor runs very fast, but no hydraulic pressure is built, the
pump may have lost its prime. This pump can lose prime if it
is run completely out of oil or if an air bubble is trapped in the
pumping chamber. An air bubble could occur during shipment,
or when the shipping plug is removed while the pump is held in
the vertical (shipping plug up) position.
a) Place the pump on a fl at, horizontal surface. Remove the
shipping plug only when in a horizontal position! Attach
an approved 10,000 psi rated hydraulic hose and cylinder
assembly to the hydraulic outlet 3/8" NPT port. Torque fi ttings
to 65-75 ft.lbs. (88-102 Nm.)
b) Attach air supply to the 1/4" NPT swivel connection. Torque to
20-25 ft. Lbs (27-34 Nm.).
c) Fill pump with only high-quality hydraulic Oil, 32 cSt hydraulic oil.
d) Prime the pump with air pressure set to 30-40 psi. If air pressure
is different than 30-40 psi follow the procedure below:
e) ON MODELS WITH TREADLE: While holding the treadle down
fi rmly in the RELEASE position, slowly depress the PRESSURE
button located under the toe of the treadle near the air supply
fi tting. Try to get the air motor to operate one or two cycles
at a time. Slowly depressing the PRESSURE button will allow
you to "throttle" the inlet air pressure
f) Pressing the operating buttons in this manner effectively draws
oil through the intake tube to refi ll the pressure chamber. You
may need to hold the treadle and "throttle" the PRESSURE
button for a few minutes to completely remove the air and
prime the pump models with an air pendant, hold "RET" button
down while cycling
g) ON MODELS WITH 4-WAY VALVES: Shift valve to neutral position,
press the treadle, and run the pump momentarily several times.
h) On models with an air pendant, hold "RET" button down while
cycling "ADV" button momentarily several times.
i) To verify that the pump is primed, operate as normal with
cylinder attached. If cylinder does not advance, repeat step
6.4g or 6.4h.
7.0 MAINTENANCE
7.1 Maintaining Proper Oil Level
Check the oil level of the pump prior to start-up, and add only
high-quality hydraulic oil, if necessary, by removing the vent/fi ll
plug (refer to Installation section, step 5.6).
7.2 Cleaning The Muffl er
Clean the muffl er every 250 hours, or more frequently if pump
is used in dirty environments. First remove 2 shoulder bolts (A)
and treadle (B). See Figure 7. To expose the muffl er, remove
2 screws (C) holding down muffl er plate. See Figure 8. Wash
muffl er element in soapy water, dry, and reassemble, installing
screws hand tight.
7.3 Changing The Oil
Change the oil every 250 hours. The vent/fi ll plug serves as a
drain plug for use in changing oil. Refi ll pump with only high-
quality hydraulic oil. Dispose of used oil properly.
7.4 Cleaning The Air Inlet Filter
Remove the swivel air connector by removing the two cap screws
and pulling air fi lter out of cavity. Using an air nozzle blow debris
off fi lter. (Always use proper eye protection). Re-install fi lter and
swivel connector. Torque cap screws to 16-18 in.lbs [1,8-2,0 Nm].