Peak Hold
When ACA or ACV is selected, pressing the PEAK button enables the peak capture circuit. The meter will now capture and display the
maximum and minimum peaks of the waveform.
INRUSH
When ACA is selected, press the INRUSH button to activate the inrush capture circuit.
A transient condition, generally lasting 110-120 milliseconds that occurs during motor
start-up.
RANGE
In the Voltage, Resistance, Capacitance, Frequency or uA function the meter automatically selects the best range for the measurements
being made. For measurement situations requiring that a range be manually selected, perform the following:
1.
Press the RANGE button. The "AUTO" display icon will turn off.
2.
Press the RANGE key to step through the available ranges. Observe the decimal point and units displayed until the preferred
range is located.
3.
To exit the Manual Ranging mode and return to Autoranging, press and hold the RANGE key for 2 seconds.
θ
COS
In power mode,
Press COS
LCD Backlight
The LCD is equipped with backlighting for easier viewing, especially in dimly lit areas. Press
will automatically turn off after 30 seconds.
Automatic Power OFF with Disable
In order to conserve battery life, the meter will automatically turn off after approximately 30 minutes. To turn the meter on again, turn the
function switch to the OFF position and then turn to the desired function position.
To disable APO:
1.
From the OFF position, hold the MODE button and rotate the FUNCTION switch to a measurement function.
2.
will appear in the display
3.
Release the MODE button
4.
APO is now disabled (APO icon is off) and will be reset when the Function switch is returned to the OFF position.
Low battery indication
When the
icon appears in the display, the battery should be replaced. Refer to the battery replacement procedure in the
maintenance section.
Maintenance
WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn
OFF the meter before opening the case. Do not operate the meter with an open case.
Cleaning and Storage
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or
solvents. If the meter is not to be used for 60 days or more, remove the battery and store it separately.
Battery Replacement
1.
Remove the Phillips head screw secures the rear battery door.
2.
Open the battery compartment
3.
Replace the 9V battery
4.
Secure the battery compartment door with the screw
You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the
household garbage is prohibited!
You can hand over your used batteries / accumulators, gratuitously, at the collection points for our branches in your
community or wherever batteries / accumulators are sold!
Disposal
Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle
Specifications
θ
button to select KVA ,KW,or Power Factor
www.tmatlantic.com
.
to turn the backlight on. The backlight
6