Aktakom AM-1171 Manual do utilizador - Página 4

Procurar online ou descarregar pdf Manual do utilizador para Multímetro Aktakom AM-1171. Aktakom AM-1171 11 páginas. Digital multimeter

Ⅳ. Description of Safety Symbols
Warning!
High Voltage! Danger!
Ground
Double Insulation
Ⅴ. Description of Instrument Panel and Pushbutton Functions
1. Instrument model.
2. LCD display area.
3. Function button: Used to select various measurement functions.
3-1"Hold" backlight switch and reading-keeping switch. If the switch is pressed over 2 seconds, the backlight turns on.
Further press the switch over 2 seconds, the backlight turns off or automatically turns off after 10 seconds. Pressing the
switch within 2 seconds could lock or unlock the data retention. Press the switch once to lock and press it again to
unlock.
3-2 Hz/DUTY: Press the key in the gear of frequency can switch
between the frequency and the Duty Cycle.Press the key in the
gear of AC Voltage or AC Curren can switch among the voltage,
current, frequency and duty cycle.
3-3 MAX/MIN: The maximum value and minimum value.Press the
function button and enter MAX mode, in which the maximum
value is held; press the button again to enter MIN mode, in which
the minimum value is held. After the MAX/MIN mode is entered,
the display device indicates the MAX/MIN value. No analog bar
display and auto power off function in this working environment.Press
down MAX/MIN button for 2 seconds, and then exit from MAX or MIN test.
3-4 Range: Automatic/Manual Range Switch. Pre-set it to automatic range when the device starts up, then switch it to
manual range. In the mode of manual range, press the "RANGE" button once, it will skip to the previous shift. When it
goes to the highest shift, it goes back to the lowest shift when the button is pressed again. The procedure repeats again in
the same order. Press the button over 2 seconds, it will exit from manual range and enter the state of automatic range
measurement.
3-5 REL: Relative Value Measurement. Press this key to show the relative value measurement, press again to cancel the
relative value measurement. The procedure repeats in the same order. Press this key over 2 seconds, it will switch to
RS232, which can be showed on the LCD screen and the RS232 data transmission is thus open. Further press the key
over 2 seconds, the RS232 icon diappears on the LCD screen. Now the RS232 data transmission terminates. The
procedure repeats.
4. "POWER"is the power switch.
5. Function Selection Button.
www.tmatlantic.com
Battery Undervoltage
AC/DC
In accordance with the instructions of European
Trade Union
Fuse
- 3 -
1
2
3-1
3-2
3-3
3-4
3-5
4
5
6
7
8
9