2) Origin Pulse output:High level≥5V(power supply voltage-1V),Low level<0.5V
Table 1
TRFM1.0□ □□□
TRFM1.0-
A
TRFM1.0-
B
Type
TRFM1.0-
C
TRFM1.0-
D
4
6
10
15
20
25
32
Nominal
drift
40
diameter
50
65
80
100
125
150
200
Explosion protection
Precision class
Turbine type
Note:
Sensors with pipe diameter of DN4~DN40 are of thread connections with maximum operating pressure of
6.3Mpa.
Sensors with pipe diameter of DN50~DN200 are of flange connections with maximum operating pressure
of 2.5Mpa.
Sensors with pipe diameter of DN4 ~ DN10 are provided with front and rear straight pipe sections and
filters.
Please specify when placing an order if flange connections are required for pipe diameter of DN15~DN40.
Please specify when placing an order for high pressure type and special requirements.
Drawing 3 Insertion Vortex Flowmeter Outline Size and Installation D
Description
Flow sensor pulse output three-wire system, +12V power
supply;
Local display, powered by 3.6V battery;
Local display with 4 ~ 20mA or pulse output, powered by
24V;
Flow transmitter 4~20mA output, powered by 24V;
Normal
flow
range
m3/h
Not marked, without explosion protection
B
Explosion protection type
A
Precision: Class 0.5
B
Precision: Class 1.0
A
Normal flow range
B
Extended flow range
4
AKTEK Endüstriyel Ekipman ve Enstrümantasyon LTD.ŞTİ.
İMES Sanayi Sitesi B-Blok 204.Sok. No:40 Y.Dudullu-Ümraniye/İSTANBUL
0.04~0.25
0.1~0.6
0.2~1.2
0.6~6
0.8~8
1~10
Extended
1.5~15
flow
2~20
range
4~40
m3/h
7~70
10~100
20~200
25~250
30~300
80~800
iagram
www.aktek.com.tr
0.04~0.4
0.06~0.6
0.15~1.5
0.4~8
0.45~9
0.5~10
0.75~15
1~20
2~40
3.5~70
5~100
10~200
12.5~250
15~300
40~800