DISTRIBUTION CONSIDERATIONS
Voltage
Do not exceed the voltage range above the use of input over the voltage range or DC
power input AC power supply will be broken or burned.
SENSOR
Load short circuit
Do not short-circuit the load will be broken or burned.
The load short-circuit hold function is the function that is used within the rated voltage
under the correct polarity of the power supply.
SENSOR
Miswiring
The polarity of the power supply, etc. Do not match the wrong line, fear of cracking or
burning.
Brown
SENSOR
Blue
No load connection
No load power supply directly into the internal prime fear will be broken or burned.
So please add the load and then wiring.
SENSOR
I
REGULAR MAINTENANCE CHECK
During the use of regular inspection, maintenance is necessary, to ensure the normal
operation of the machine. Periodically check items as follows:
• When the object is detected, whether the switch is in the distance, whether there is a loose
phenomenon, whether there is a tilt correction, whether the inspection has changed.
• Wiring or other connection lines, whether the contact is normal, or no break.
• Does the sensor face dust?
• Check operating temperature, and the surrounding environment is suitable.
• lnstal lation space, whether there has difference, such as vibration, electrical leakage ..
Other :
When the power is applied, the sensor needs 1 00ms lead time, in order to achieve stable
output of the sensor, so during this time, do not operate the sensor. Avoid being applied to
the outside (except for shelter).
• Avoid direct contact with organic solvents.
• To prevent the detection surface by the impact of objects, because the sensing surface is
very fragile.
• When the device or motion switching power supply can not be too pull, move.
I
PRECAUTIONS
• Make sure that the power is turned off when connection.
• Make sure that the supply voltage changes within the rated range.
• If the power supply is supplied by a commercial switch regulator, make sure that the
Brown
power supply ground terminal (F.G) is grounded.
Blac
• Be sure to ground the device ground terminal (F.G).
• Do not use when power on within 0.Ss.
• Do not run the line with a high voltage line or a power cord or in a wire tube, which may
cause malfunction due to induction.
• Avoid dust and water vapor.
Brown
• Do not expose the sensor to direct contact with water, oil, grease or organic solvents, such
Blue
as thinner.
Black