7
ATTACH CABLE CONNECTOR
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4" O.D.
Fig. B.
8
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then refer
to the "troubleshooting section" of these instructions.
9
MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED
AND MUST BE PURCHASED SEPARATELY.
Thread TEE BODY (4) to SPOUT SHANK (5).
Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).
Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use
adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
Fig. A.
1
1/2" PIPE THREAD
2
FLEXIBLE
SUPPLIES
HOT
3
Fig. B.
1
2
2
5
6A
7
4
6
WASTE
OUTLET
3/8 COMPRESSION
CONNECTION
1-1/4" O.D.
1
1A
7A
COUPLING
NUT
3
3/8 O.D.
BULL-NOSE
RISERS
COMPRESSION
NUT
FERRULE
COLD
M 9 6 5 015 R E V. 1. 7