PIPING PREPARATION
Unit: mm
2
MARK MOUNTING HOLES
A.
A.
Insert the flange into the waste outlet
pipe, ensuring that the arrow is pointing
toward the floor.
3
PUNCHING
305/400mm
Using
Ø10mm masonry drill bit, drill the floor to
connect the floor fixing set, follow floor fixing set,
follow in the figures.
WATER SUPPLY PIPE : Connecting size G1/2".
WASTE PIPE : Size Ø108mm or 102mm (PVC, Pipe
Class 8.5 or a regular pipe with an internal diameter
of 108mm or 102mm at the connecting point with the
toilet and a gradient of 2cm, per 100cm.)
Remark: Ø108mm is for Korea, Ø102mm is for China.
AIR VENT : Size not smaller than Ø1-1/2" and must
connected directiy to the waste pipe.
B.
B.
Set proprely the VC on the floor, mark the
location to be drilled. (the figure just as
reference)
4
INSTALL FLOOR FIXING SET
10mm.
drill
305/400mm
Install the floor fixing set and plastic trapway at the
assigned location.
- 2 -
Dec.14
Rev.01