American Standard ACONT202AS11MA Manual de instalação e do utilizador - Página 3

Procurar online ou descarregar pdf Manual de instalação e do utilizador para Termostato American Standard ACONT202AS11MA. American Standard ACONT202AS11MA 12 páginas.

American Standard ACONT202AS11MA Manual de instalação e do utilizador
2.

Product Specifications

Heat (@ 6°F/Hr)
Cool (@ 6°F/Hr)
Gas, Oil, Electric, (mV and 24V), Heat Only, Cool Only or Heat/Cool Systems
3.

General Information

3.1

Overview

The 202 is a programmable push button single stage
thermostat with a 3.5'' backlit display. The 202 features a
scheduling mode that can operate a 7-day program, 5-1-1
program or operate in a non-programmable mode.
3.2

Contents

— 1-Thermostat
— 1-Sub-base
— 2-Phillips slotted head mounting screws
— 2-Nylon Drywall Anchors
— 1-Installation Guide / User Guide
3.3

Accessories

Wall Cover Plate (BAYCOVR200A)
Pub. No.
11-HD20D1-1A-EN
SPECIFICATION DESCRIPTION
Product Models
Configurations
Maximum Number of Stages
Operating Temperature
Shipping Temperature Range
Input Power (DC)
Input Power (AC)
Wire Usage
System Modes
Fan Modes
Cooling Setpoint Temperature Range
Heating Setpoint Temperature Range
Temperature Display Range
Minimum Cycle Off Time Delay
Terminal Load
Operating Ambient
Shipping Temperature Range
RATED DIFFERENTIALS
FAST
0.5°F
0.9°F
THERMOSTAT APPLICATION GUIDE
Thermostat Applications
12/2018
37-7778003
Part No.
American Standard 202 Programmable Thermostat
ACONT 202
Product
202
Size
3-3/4" x 6" x 1-1/8 (HxWxD)
Heat / Cool
1H, 1C
32°F to 105°F (0 to +41°C) / 90% RH Non Condensing
-20 to 150°F (-29 to +65°C)
Two 1.5V AA Alkaline
20 - 30 VAC, NEC Class ll, 50/60 HZ
18 AWG
Heating, Cooling, Off
Auto, On
45°F to 99°F, 1°F resolution
45°F to 99°F, 1°F resolution
32°F to 99°F, 1°F resolution
Compressor: 5 minutes, Indoor Heat; 1 minute
1.0A per terminal, 1.5A maximum all terminals combined
32°F to +105°F (0° to +41°C)
-20°F to +150°F (29° to +65°C)
MEDIUM
0.75°F
1.2°F
4.

Installation

4.1

Location

The 202 is designed for installation in climate controlled living
spaces. Place the unit in a central location with good circulation.
For proper temperature sensing, avoid exposing the 202 to heat
radiated from lamps, sun light, fireplaces or any other radiant heat
source.
Avoid locations close to windows, behind doors or alcoves with
poor air circulation, adjoining outside walls, or doors that lead to
the outside.
Select a location that prevents the 202 from being directly exposed
to air currents from supply registers or ceiling fans.
Mount the Control on a section of interior wall that does not
contain hot or cold water pipes or duct work.
SLOW
1.9°F
1.7°F
Maximum Stages Heat/Cool
1/1
3