American Standard FLUENT 7186.801 Manual de instruções de instalação - Página 4
Procurar online ou descarregar pdf Manual de instruções de instalação para Cozinha & amp; Acessórios de casa de banho American Standard FLUENT 7186.801. American Standard FLUENT 7186.801 7 páginas. Wide spread lavatory faucet
10
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water
lines thoroughly.
Replace AERATOR (3).
11
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (5) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If STOPPER (4) does not seal properly, please
refer to "Troubleshooting Guide" in these instructions.
Release POP-UP KNOB (5) down and check all drain
connections and "P" trap for leaks.
if necessary.
12
SERVICE
To change direction of handle:
Turn valves to OFF position.
Turn off water supplies.
Loosen SET SCREW (1) with 5/64" HEX WRENCH (2).
Pull HANDLE (3) "UP" firmly to release from
PLASTIC INSERT (4, 5 or 6).
Remove SCREW (7) and pull off PLASTIC INSERT
(4, 5 or 6).
Remove RETAINING O-RING (8).
Lift and turn STOP WASHER (9) 90˚.
Replace RETAINING O-RING (8).
Re-install HANDLE ASSEMBLY.
AERATOR may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
13
CARE INSTRUCTIONS:
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES,
HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
Tighten
and rinse to clear any debris.
5
1
WASTE
OUTLET
2
HOT
2
1
7
9
90˚
4
3
4
2
COLD
"P" TRAP
3
4
RED
5
BLUE
6
8
9
90˚
M965622 Rev. 1.2 (12/17)