Procurar online ou descarregar pdf Manual para Ferramentas Amerisun PowerSmart DB7651. Amerisun PowerSmart DB7651 6 páginas. Auger belt tension adjustment

Auger Belt Removal – DB7651
WARNING Entanglement Hazard -
performing any service procedures, make sure the
engine is off and remove the spark plug wire from the
spark plug to ensure the engine cannot accidently start.
Note: Record component position before disassembly, to
assist in reassembly.
1. Disconnect the upper cable from the auger control
handle.
2. Remove 2 hex head screws and remove belt cover.
3. Loosen the belt guide pin hex head screw (installed
on engine crankcase) and rotate the pin away from the
pulley.
Before
4. Left Side - Loosen the hex nuts attaching the auger
housing to the main frame.
5. Right Side – Remove the hex nuts, lock washers and
flat washers attaching the auger housing to the main
frame.
Rev 1.0 4-11-13