15. PROGRAMMING
Adjustment of Dip-switches
at change of position of dip-switches or mechanical regulators
It is necessary to switch off and again to include the drive power
supply. otherwise change of options will not occur.
stop from impulse command than
moving
separate control start – opens,
ped - closes
Motor position near the gate
type of limit switches
Connection of DHRE-2 reciever
external receiver dHre-2 is meant for receiving radio remote control signal with 433 MHz frequency,
decoding it and control signal actuating.
Installation
1. Connect your receiver to a power supply 12/24 V, aC/dC by using input terminals +24V and gnd.
2. Connect the operator control board n.o. operating inputs to receiver output terminals CH1 or CH2.
Memory clearing
3. Before encoding you can clear the receiver memory from the previously stored codes (it is
recommended at the first setting). to perform it, when the power is switched on, press Code button for the
10 seconds (Code1 (or sW1) - if you are using CH1, Code2 (or sW2) - if you are using CH2). led1 will be
flashing 10 seconds then switch off for 2 seconds and flash twice to confirm that the memory is clear.
Encoding
4. For encoding a transmitter code to the receiver press Code button for 3 seconds on the receiver
board (Code2 (sW2) for the operator connected to CH1 and Code1 (sW1) for the operator connected to
CH2) led1 will light. after that press a button on the transmitter twice.
Attention! after this operation only 1 button of the transmitter is stored in the receiver memory.
5. For encoding another transmitters repeat the procedure.
Connection
For connection a receiver to a control board it is needed to connect the output control terminals (CH1
or CH2) and the power supply terminals (+24V, gnd) to a control board.
17. REPAIRS
For repairs, contact doorHan's authorized repair Centers
18. MAINTENANCE
sliding type opener is an environmentally friendly product generally requiring a minimum of maintenance in normal use.
after a period of time in use, regularly check whether the door is balanced when opening/closing, whether the spring has enough force to raise
the door.
In the case of power failure the operator can search for the program memory. When the power is restored, press the button of the transmitter
once, the door will rise.
run a functional check of the system at least every 6 months, with special attention to the efficiency of the safety and release devices.
the manufacturer reserves the right to make alterations and modifications of the construction without preliminary notice.
the present directions describes installation and adjustment operations of the road gate BarrIer-5000.
Following the recommendations on operation, maintenance of the road gate as well as installation operation sequence of the operator and the door
given in the directions will ensure long life of the equipment and reduce the possibility of accidents during installation and operation of the door.
observe accident prevention rules while installation and operation.
In case of loosing of the present directions you may request for its duplicate to the following address: 36 Moghaiskoye shosse, Moscow 121354
or e-mail: [email protected].
the manufacturer (doorHan) does not handle direct control of installation, maintenance and operation of the doors and the automatics and shall
not be responsible for safety of installation, maintenance and operation of the doors, road gates and the automatics.
Contents of the directions shall not be basis for any claim.
11
Yes
no
Yes
no
right
left
I n s t a l l a t I o n a n d o p e r a t I n g M a n u a l o p e r a t o r s l I d I n g - 1 3 0 0 / 2 1 0 0
16. Radio controls encoding
Recording of remote controllers
setting of control with radio channel of remote controllers
doorHan:
1.
Before programming you can clean the memory of the receiver,
erasing all former codes. (it is recommended by first setting) turn on
the power supply and hold down record key for 10 sec. the indicator
«а» will be blinking for 10 sec, then it will become dim and in 2 sec. it
will blink twice to confirm erasing of the former codes.
2.
In order to record the code of the remote controller hold down
for 3 sec the record key. the read indicator «а»should blink. release
the key. While the red indicator is blinking, hold down for 10 sec
the selected key on the remote controller (the key, that you want
to control the unit). Hold down the key on the trinket until the red
indicator «а» lights for 2sec and then goes out, to confirm that the
remote controller code is stored in the memory of the receiver.
3.
to make setting of several Для настройки нескольких пультов
повторите запись кода для других пультов. You can make setting
of 65 remote control units.
If the receiver not receives the command in 10 sec, it exits the waiting
mode automatically. after the control unit is disconnected from the mains,
all programmed data are stored.
PRoGRAMMInG
11