4. START-UP
1. Only in the KEOPS housing. Remove the two covers from the housing to begin
start-up. Unscrew the screws that attach the cover to the housing, before lifting it.
2. Open the filter and fill it halfway with water. Protect the diffuser in the interior of
the filter so sand does not get into it.
3. Fill the filter with the appropriate quantity (indicated on the specifications label,
or up to 2/3 of the total filter height) of silex sand with a grain size of 0.4 - 0.8.
4. Assemble the T manometer, the seal, the manometer and the air purge cover.
Teflon tape is not necessary, as this point is sealed by the seal. Do not tighten the T
of the manometer with any tools; it is enough to do this with the hand.
5. Clean the remnants of silex from the mouth, cover and casket housing, and close
the filter. For more information, please consult the filter manual.
If the unit is below the water level, you will only need to open the input and output
valves and the air vent until the filter and the pump are full of water.
6. Put the valves in the following positions:
- SKIMMER
- SUMP
- POOL CLEANER
- RETURN
- SELECTOR VALVE
OPEN
OPEN
OPEN
OPEN
WASH
7