Procurar online ou descarregar pdf Manual para Equipamento de iluminação Astrapool Dual Pure 40. Astrapool Dual Pure 40 20 páginas. Salt electrolysis and ph regulation
ADJUSTING THE DURATION OF THE POLARITY INVERSION
Your salt chlorinator was programmed in the factory for a polarity change every 4 hours.
According to the hardness of the water (TH for degree of Total Hardness), it is possible to change this
cycle from 1 to 99 hours.
Switch off the device
-
Press
and
-
Keep
and
-
Press Menu, DUR appears.
-
Press Menu, the duration of the polarity inversion is displayed; press
value.
-
Press Menu to confirm
SELF TEST:
Warning! Water temperature > 23°C, minimum salt content 4g/l.
This function allows one to check the state of the electrode and that the unit is working properly.
Press the "TEST" key.
The LEDs light up,
Then "prod 1" followed by "prod2".
If all of the LEDs flicker after 30 seconds, then the test is OK.
CHECKS AND MAINTENANCE
CHECK THE PARAMETERS:
Press "MENU" for two seconds,
Scroll through the functions using
Then press "Menu" to visualise:
-
DUR duration of the polarity inversion (self-cleaning expressed in hours).
Factory setting: 4
-
FE: regulates production according to the position of the cover.
Percentage of production depends on the cover being in the closed position.
Factory setting: 50%
-
INT: intensity sent to the electrode (expressed in amperes).
simultaneously while switching on the device.
pressed until the screen displays ATT then PRO.
or
,
12
Número de revisión
ENGLISH
or
to change the