Air Fantastic CAP5000 Manual do Proprietário - Página 13
Procurar online ou descarregar pdf Manual do Proprietário para Filtro de ar Air Fantastic CAP5000. Air Fantastic CAP5000 16 páginas. Central air purifier (cap)
2.
Using a 1/4" hex head screw driver, remove the four screws securing the Bal-
last Assembly and pull the Ballast Assembly away from the Retainer Ring until
the four pins have completely disconnected from the Ballast Assembly.
3.
Using a 1/4" hex head screw driver, remove the four screws securing the
Quad-Ion Cell and pull the Quad-Ion Cell out from the Retainer Ring. Properly
dispose of the Quad-Ion Cell. The four screws will be needed in step 4.
Maintenance (Continued)
Be sure to insert the
Quad-Ion lamp with the
opening facing the air
flow.
11