Astrel Group E4U-PRO-15 Manual de instalação e de instruções - Página 3
Procurar online ou descarregar pdf Manual de instalação e de instruções para Inversor Astrel Group E4U-PRO-15. Astrel Group E4U-PRO-15 9 páginas.
4-noks
Elios4you Pro
Code
Name
E4U-PRO-15
Elios4you Pro up to 15 kW
E4U-PRO-50
Elios4you Pro up to 50 kW
E4U-PRO-100
Elios4you Pro up to 100 kW
Read and keep these instructions
General description
Elios4you Smart is a monitoring device used with photovoltaic systems for managing self-consumption
of three-phase consumers rated 15kW, 50kW or 100kW (depending on the model)
Users can configure and monitor the production of their photovoltaic system simply and intuitively by
way of the "Elios4you" App.
Products compatible with Elios4you Pro
Pro Smart
9
Power Reducer
9
4-cloud (web service)
9
Contents of the pack
1 x Elios4you Pro
9
1 x external antenna
9
6 x split core CT (current transformer)
9
Safety warnings
All hardware connections must be made by a person who is suitably qualified and aware of the risks
associated with installation, observing the requisite standards of safety, and with the equipment isolated
from the power supply.
The user accepts all responsibilities and risks connected with the steps of installing, configuring and
using products to the end of obtaining the benefits and advantages they afford. The liability of the Astrel
Group in respect of its products is regulated by the Astrel Group General Conditions of Sale (published on
the company's website www.astrelgroup.com).
Do not disassemble, open up or attempt to repair the product. Opening up a sealed component has the
effect of invalidating the warranty.
Installation
Prior to installation
Before installing the Elios4you device, remove the label illus-
ID CODE: 00000
trated alongside, which indicates the USER code.
Keep the label: it will be used for configuring other mobile de-
Register on:
www.4-cloud.org
vices with Elios4you and possibly accessing the
and pair your device
org
portal (accessory service available in the case of configura-
with USER: XXXXXXXX
tions with router/AP).
When a device is configured via Router/AP, the pertinent data can be seen on the portal about one hour
after the configuration.
Warnings for installation
Parts indicated as carrying dangerous voltage, live inputs, current probes and the relay output, must be
protected against the risk of causing electric shock using connections with double or reinforced insula-
tion, connecting cables included.
The instrument must be installed in an electrical cabinet affording the appropriate protection against access
to dangerous live components, as well as guaranteeing the disconnection of live parts generally, if necessary.
The disconnect breaker is to be provided by the installer and must meet certain requirements, namely:
it must be located in an easily accessible place
9
it must be clearly identified as a component used to disconnect the device.
9
The installer must provide overload protection for the relay, if utilized.
If the device is used in a manner not specified by the manufacturer, the effectiveness of the protection
provided could be jeopardized.
Any repairs on the appliance must be entrusted only to persons authorized by the manufacturer.
4-NOKS is a brand of ASTREL GROUP
ASTREL GROUP SRL
/
Via Isonzo, 21/E
/
34070 Mossa (GO) Italy
/
www.astrelgroup.com
/
www.4-noks.com
Installation and instruction manual
Fixing and first power-up
1)
Fix the device to a DIN rail, making the connections as in the installation diagram (Fig. 2).
Caution: if the CT cable needs to be extended, it is advisable to use a 2x0.75mm
cable of length not exceeding 20 m.
2)
Having installed and powered up the device, download the free "Elios4you" App for tablet or
smartphone from App Store or Google Play Store, and proceed to install it
3)
Launch the "Elios4you" App and follow the steps of the guided configuration procedure, screen
by screen.
For more information, go to www.4-noks.com/tutorial.
4)
Set the correct parameters of the photovoltaic system and the household electrical consumer
by way of the App: Menu
"System Parameters"
and enter the preferred values. On completing the operation, tap OK.
5)
For more information, go to
www.4-noks.com/tutorial
Check installation
6)
Check on this page that all items of data are correct:
• Tap the "Home" icon
to go back to the "System activity" page
www.4-cloud.
• Make certain that the value of the power output — "Production"
the reading of the inverter
• Check whether or not the "Consumption" value corresponds to instantaneous usage by the
monitored consumer
CAUTION: when Elios4you is configured for access to the internet (via Router/AP), the data log will also
be sent to the 4-cloud portal. Connect to the cloud site
www.4-cloud.org
registration. Adopt the USER code indicated on the label for pairing the device.
Response of Leds (table 1)
Led Colour
Meaning
Production of photovoltaic energy. Blink frequency proportional to the
Red
amount of energy generated by the photovoltaic system.
Blink frequency proportional to the amount of energy exchanged with
Red
the grid.
Green
Power supply
Green
Wi-Fi active
60 mm
Led Colour
Meaning
2
screened
Red
No connection between Elios4you and tablet or smartphone
Green
Not used
CAUTION: ensure that there are no other consumers connected between the CTs and the relative
meters, or branches, otherwise the measurements will not be correct
Operation of button (table 2)
select "Energy Management"
Function
Command
Meaning
Procedure required by the "Elios4you" App when the
Press briefly
First configuration
device is first configured. For more information:
(6 second approx)
noks.com/tutorial
— corresponds to
Press and hold
The Reset function restores the parameters of the
Reset
(30 seconds
device to the factory settings
approx)
Technical specifications
and follow the instructions for
Control system for three-phase photovoltaic systems with Wi-Fi
General specifications
connection and App for smartphone/tablet.
Maximum measurable power 15 / 50 / 100 kW (depending on model)
Power supply
400V (3x 230Vac + neutral) ± 10% 1.8 W
/
Wi-Fi 802.11b/g/n
Radio specifications
/
Access point (AP) Station (STA), B,G,N or mixed mode
Data log up to two months, in the event of no connection to tablet, with
Memory
sampling every 15 minutes
Status displays
6 x Led
Screw terminals for power connections, measurement CTs, alarm inputs
Connections
and control outputs
How to access the button
Fig. 1A: Remove the cover on the right hand part of the device
105 mm
Fig. 1B
Current measurement
With split core CT (internal Ø 15 mm max)
External antenna on SMA RP screw connector for data transmission via
Antenna
Wi-Fi
/
Relay output (max 10A @ 230Vac)
Outputs
/
Control output 0-10Vdc
Inputs
2 x voltage-free alarm contact (N.O.)
/
Operating conditions: 0 to +50°C; <80% R.H., non-condensing
Ambient parameters
/
Storage conditions: -20 to +70°C; <80% R.H., non-condensing
Degree of protection
IP20
Dimensions (L x H x D)
6-module DIN rail housing 105 x 110 x 60 mm
www.4-
Troubleshooting
1) Main screen of the "Elios4you" App never shows power produced by the photovoltaic system
Turn the production CTs (white label) about face, so that the green dot or the arrow on the
9
inside of the CT is positioned on the opposite side to that currently in use.
Check that the cores of the CTs do not show any signs of internal damage.
9
2) Power level displayed by the App is much lower than that read by the inverter
Check that the grid CTs (yellow label) are positioned around the entire bundle of phases
9
coming from the meter as in the diagram (see fig. 2); it is possible that the CTs may have been
placed on a branch circuit.
Check that one or more CTs do not show any clear signs of damage internally.
9
3) Consumption detected and power produced follow the same curve
Check that the grid CT (yellow label) is positioned around the entire bundle of phases coming
9
from the power company meter as in the diagram; in all probability, only the cable carrying
consumption data is being detected.
Check that only the phase conductor of the system passes through the two CTs: if both phase
9
and neutral pass through, an error will be induced.
Check that the two CTs do not show any clear signs of damage internally.
9
4) Power usage by the consumer appears to be detected in the grid icon
Check that the grid CTs (yellow label) are positioned on the lines leaving the relative meter,
9
upstream of any branch made within the electrical system.
+05T408110R3.0 Elios4you Pro Instruction manual IT-EN-FR-DE
Astrel Group reserves its rights to make changes or variations to its own products without any prior notice
Button
/
20.12.2016
/
p. 3/8