Astrel Instruments AST-8300-A Manual do Automanualr - Página 8
Procurar online ou descarregar pdf Manual do Automanualr para Sistemas de filtragem de água Astrel Instruments AST-8300-A. Astrel Instruments AST-8300-A 14 páginas.
Também para Astrel Instruments AST-8300-A: Começar a trabalhar (20 páginas), Manual do utilizador (6 páginas)
Astrel Instruments
AST-8300-A
CALIBRATION
It is necessary to calibrate the autoguide before the start of the guiding. To do this you
have to complete at least one procedure - determination of the orientation of the celestial
reference frame in the image, taken from the camera. In addition, it is advisable to perform
camera calibration with the dark frame.
Determination of the orientaion of the celestial reference frame
Direct your guide to the star you'd like to use for guiding. Make sure that the star isn't near
the image edge. Focus the image. Make sure that all mountings are tightened and the
wires do not hang freely.
Open 'Processing' -> 'Calibration' from the main menu. The Calibration window is opened
and can be moved if needed for monitoring the guide star.
Use the 'two axes' parameter to choose the two-axes or one-axis calibration. If the polar
axis is aligned, it is recommended to use the automatic mode of calibration - parameter
'auto mode'.
Autoguider Manual
8/14
rev A