10' FOOT RULE
All chimney terminations must extend a minimum of 3 feet above the
highest point where it passes through the roof and must be at least 2
feet above roof with a 10 foot horizontal span (see Figure 20).
IMPORTANT: If an exposed portion of chimney is greater than 4 feet
above the roof line, use support wires to keep chimney secure. Sup-
port wires may be attached to outer pipe of chimney with screws, if
screws do not penetrate inner flue pipe.
Figure 20- 10 Foot Rule
MINIMUM/MAXIMUM CHIMNEY HEIGHT
The minimum height of the chimney (measured from the base of the
fireplace to the flue gas outlet-end of pipe) is 16 feet for a straight run,
16 feet minimum for a run with 1 elbow set and 25 feet minimum for
a run with 2 elbow sets. (A set consists of one starter elbow and one
return elbow.)
Uncommon circumstances such as neighboring hills, tall trees, or
strong wind areas can cause down drafts in chimney system. In such
cases, going beyond the minimum recommended height would be
preferable to provide a better draw.
The fireplace height approved for any chimney run with this fireplace
system is 40 feet measured from bottom of firebox to flue outlet-end
of pipe (see Figure 21).
10
VENTING INSTALLATION Continued
Storm
Collar
PENETRATING ROOF
To maintain a 1" clearance to pipe on a roof with a pitch, a rectangular
opening must be cut.
1. Determine center point where pipe will penetrate the roof.
2. Determine center point of the roof. Pitch is the distance the roof
drops over a given span, usually 12". A 6/12 pitch means that the
roof drops 6" for each 12" measure horizontally down from roof
rafters.
3. Use roof opening chart (Figure 22, page 11) to determine correct
opening length and flashing required.
4. Remove shingles around opening measured. Cut out this section.
Astria.US.com
RTL-8DM
RTL-8DM
Flashing
MINIMUM
HEIGHT
15 FT.
(4.5m)
Firestop
Spacer
Figure 21 - Maximum Chimney Height
ETL-8DM
MAXIMUM
HEIGHT
CHASE
TERMINATION
40 FT.
(12m)
126650-01B