Astria StarLite42WH Manual de Instruções de Instalação e Operação - Página 8

Procurar online ou descarregar pdf Manual de Instruções de Instalação e Operação para Lareira de interior Astria StarLite42WH. Astria StarLite42WH 18 páginas. Indoor and outdoor vent-free firebox

Astria StarLite42WH Manual de Instruções de Instalação e Operação
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this firebox involves
installing firebox into a framed-in enclosure.
This makes the front of firebox flush with
wall. If installing a mantel above firebox, you
must follow clearances shown in Figure 4.
Follow these instructions to install firebox
in this manner.
1. Frame in rough opening. Firebox framing
should be constructed of 2 x 4 lumber
or heavier. Use dimensions in table and
rough opening layout in Figure 6a.
Adjust framing so that firebox is flush
with finished wall surface. If installing
in a corner, use dimensions in Figures
6b, 6c and 6d for rough opening.
2. Install gas piping to firebox location. See
Installing Gas Line, Page 10 and Con-
necting to Gas Supply in log set owner's
manual.
3. Carefully set firebox in front of rough
opening with back of firebox inside wall
opening.
4. Carefully insert firebox into rough opening.
5. Attach firebox to wall studs using nails
or wood screws through holes in nailing
flange (see Figure 5).
6. Install and properly test gas log heater.
Follow installation instructions included
with vent-free gas log heater that is being
installed.
8
INSTALLATION Continued
Combustible Materials
Allowed Flush With
1/2" Airspace Clearance
To Sides And Back
No Material Within
The Face Opening
Non-combustible Material
Only (field provided) May
TOP VIEW
Overlap the Face
Figure 5 - Minimum Mantel Clearances for Built-In Installation
Optional
Hearth
Extension
Figure B
Astria.us.com
The Face Front
Non-combustible Material
Only (field provided)
5"
Non-combustible Material
Only (field provided) May
Overlap the Top Face
Do NOT Overlap
Material Within
The Face Opening
No Material
Allowed in
This Area
Combustible Material
May Overlap The
Face Bottom Up To 2"
Below The Face Opening
16"
16" (407mm)
Optional
Hearth
Extension
1/2" Airspace Clearance
To Sides And Back
1/2" Clearance
Nailing Flange May
Make Direct Contact
With Combustible
Framing
No Combustibles
Below The Top Spacers
1/2"
Airspace
Clearance
To Back
SIDE VIEW
40"
40"
(1016mm)
900977-00A