AMES 1000a Manual do proprietário e instruções de segurança - Página 8

Procurar online ou descarregar pdf Manual do proprietário e instruções de segurança para Instrumentos de medição AMES 1000a. AMES 1000a 16 páginas. Ac/dc trms digital clamp meter

AMES 1000a Manual do proprietário e instruções de segurança
Operating instructions
read the entire iMpOrtant SaFety inFOrMatiOn section
at the beginning of this manual including all text under
subheadings therein before set up or use of this product.
electrical shock can cause death or injury! neVer tOucH
exposed conductors of
General Operating instructions
reL/inruSH
1�
Press the reL/inruSH button
once to enter relative measurement
mode and store a reference value�
2�
Take additional measurements to
display difference between measured
value and reference value�
Manual range
The Meter's default range is autO� To select manual range, press ran� Each press
of the button increases the range� Hold the ran button to return to auto-range�
note: Manual range cannot be used while measuring frequency�
Frequency and Duty cycle Measurements
1�
While working with voltage or
current ranges, press the Hz%
button one time to measure the
frequency of the voltage or current�
2�
Press the Hz% button twice to
measure the duty cycle of the voltage
or current� The range is set to manual�
Minimum and Maximum Value Measurements
1�
Press the Min/MaX button one
time to measure the maximum
value at any range�
2�
Press the Min/MaX button
two times to measure the
minimum value at any range�
3�
Press the Min/MaX button three times
to display difference between maximum
and minimum measurements�
Page 8
electricity.
For technical questions, please call 1-888-866-5797.
3�
Hold reL/inruSH button for two or
more seconds to enter inrush mode�
note: Relative measurement mode can
only be used in manual range mode�
3�
Press the Hz% button a third
time to return to normal voltage
or current measurement�
note: Frequency and duty cycle
modes cannot be used while in
minimum or maximum value mode�
4�
Hold the Min/MaX button
for one or more seconds to
return to normal mode�
note: The Meter is automatically set to
manual range mode when measuring
minimum or maximum value�
note: Frequency and duty cycle modes
cannot be used while in minimum
and maximum value mode�
Item 64017