1.1 Connect the live wire of AC power supply to terminal "L / +" of INPUT, and connect the neutral wire of AC power supply to terminal "N / -" of
INPUT.
1.2 Connect terminal B to the positive pole of DC power supply, connect terminal C to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
2) If you want to control an AC 220V lamp, do as following:
2.1 Connect the live wire of AC power supply to terminal "L / +" of INPUT, and connect the neutral wire of AC power supply to terminal "N / -" of
INPUT.
2.2 Connect terminal B to the live wire of AC power supply, connect terminal C to one side of AC lamp, and connect another side of AC lamp to the
neutral wire of AC power supply.
Setting different control modes :
We have set the receiver in toggle mode before delivery, if you want to use other modes, do as following operation.
1) Setting control mode Toggle (with transmitter CC-4): Turn on the first bit of the dip switch.
Control mode Toggle: Press -> On; Press again -> Off.
Press button A of the transmitter: Turn on relay1 (connect A and B, disconnect A and C),the lamp 1 is turned on.
Press button A again: Turn off relay 1 (disconnect A and B, connect A and C), the lamp 1 is turned off.
Press button B of the transmitter: Turn on relay2 (connect A and B, disconnect A and C), the lamp 2 is turned on.
Press button B again: Turn off relay 2 (disconnect A and B, connect A and C), the lamp 2 is turned off.
Press button C of the transmitter: Turn on relay3 (connect A and B, disconnect A and C), the lamp 3 is turned on.
Press button C again: Turn off relay 3 (disconnect A and B, connect A and C), the lamp 3 is turned off.
Press button D of the transmitter: Turn on relay 4 (connect A and B, disconnect A and C), the lamp 4 is turned on.
Press button D again: Turn off relay 4 (disconnect A and B, connect A and C), the lamp 4 is turned off.
2) Setting control mode Momentary (with transmitter CC-4): Turn on the first and the second bits of the dip switch.
Control mode Momentary: Press and hold -> On; Release -> Off.
Press and hold button A of the transmitter: Turn on relay 1 (connect A and B, disconnect A and C), the lamp 1 is turned on.
Release button A: Turn off relay 1 (disconnect A and B, connect A and C), the lamp 1 is turned off
Press and hold button B of the transmitter: Turn on relay 2 (connect A and B, disconnect A and C), the lamp 2 is turned on.
Release button B: Turn off relay 2 (disconnect A and B, connect A and C), the lamp 2 is turned off.
Press and hold button C of the transmitter: Turn on relay 3 (connect A and B, disconnect A and C), the lamp 3 is turned on.
Release button C: Turn off relay 3 (disconnect A and B, connect A and C), the lamp 3 is turned off.
Press and hold button D of the transmitter: Turn on relay 4 (connect A and B, disconnect A and C), the lamp 4 is turned on.
Release button D: Turn off relay 4 (disconnect A and B, connect A and C), the lamp 4 is turned off.
3) Setting control mode Latched (with transmitter CC-4): Turn on the second bit of the dip switch
Control mode Latched: Press -> On, other relays Off; Press another button -> Off.
Press button A: Turn on relay 1, the lamp 1 is turned on. And turn off other three relays at the same time, other three lamps are turned off.
Press button B: Turn on relay 2, the lamp 2 is turned on. And turn off other three relays at the same time, other three lamps are turned off.
Press button C: Turn on relay 3, the lamp 3 is turned on. And turn off other three relays at the same time, other three lamps are turned off.
Press button D: Turn on relay 4, the lamp 4 is turned on. And turn off other three relays at the same time, other three lamps are turned off.
Wired control terminals:
The receiver has wired control terminals, you can connect external devices, sensors, limit switches or manual switches to trigger the receiver.
1) By low level signal:
You can connect external devices (with low level output signal) to trigger the receiver.
When external device outputs low level signal to terminal "COM" and "Signal 1", turn on the relay 1, and the lamp 1 is turned on.
When external device stops to output signal, turn off the relay 1, and the lamp 1 is turned off.
When external device outputs low level signal to terminal "COM" and "Signal 2", turn on the relay 2, and the lamp 2 is turned on.
When external device stops to output signal, turn off the relay 2, and the lamp 2 is turned off.
When external device outputs low level signal to terminal "COM" and "Signal 3", turn on the relay 3, and the lamp 3 is turned on.
When external device stops to output signal, turn off the relay 3, and the lamp 3 is turned off.
When external device outputs low level signal to terminal "COM" and "Signal 4", turn on the relay 4, and the lamp 4 is turned on.
When external device stops to output signal, turn off the relay 4, and the lamp 4 is turned off.
2) By NO/NC contact:
You can connect manual switches (with NO/NC contact) to trigger the receiver.
When connect terminal "COM" and "Signal 1" by manual switch, turn on the relay 1, and the lamp 1 is turned on.
When disconnect terminal "COM" and "Signal 1" by manual switch, turn off the relay 1, and the lamp 1 is turned off.
When connect terminal "COM" and "Signal 2" by manual switch, turn on the relay 2, and the lamp 2 is turned on.
When disconnect terminal "COM" and "Signal 2" by manual switch, turn off the relay 2, and the lamp 2 is turned off.
When connect terminal "COM" and "Signal 3" by manual switch, turn on the relay 3, and the lamp 3 is turned on.
When disconnect terminal "COM" and "Signal 3" by manual switch, turn off the relay 3, and the lamp 3 is turned off.
When connect terminal "COM" and "Signal 4" by manual switch, turn on the relay 4, and the lamp 4 is turned on.
When disconnect terminal "COM" and "Signal 4" by manual switch, turn off the relay 4, and the lamp 4 is turned off.