Colasit CDVA 560 Manual de operação - Página 10
Procurar online ou descarregar pdf Manual de operação para Ventilador Colasit CDVA 560. Colasit CDVA 560 16 páginas. Roof fan in plastic
Warning
Do not turn power on or off without prior warning to persons in the area where the fan is
operating. Switching operations must be co-ordinated with other functions in the working
area of the fan.
5
Operation
5.1
Safety instructions
The fan must be operated according to this manual. This will avoid the occurrence of any
damage.
Supervision
The fan must not be operated unattended as long as it conveys substances whose
reactions are unknown or if unexpected reactions are anticipated.
If supervision must be withdrawn for operational reasons, this must be reported to the
safety officer and the system must be secured in such a way that no unauthorized
intervention can be carried out. The safety officer must decide on issues regarding
supervision.
5.2
Putting out of operation
An internal process instruction must regulate the work to be carried out as well as the preparatory work for
putting back into operation (e.g. cleaning).
6
Maintenance, repair, cleaning
6.1
Preparation
Before any work is carried out on the fan, the fan must be set to its "safety position".
The „safety position" is defined as follows:
-
The drive must be currentless and the main switch secured against switching on,
The fan impeller can be manually rotated,
-
-
Fan must be flushed with fresh air and be condensate-free,
-
Fan must be at room temperature,
-
Personal protective equipment must be available and it must be worn. (Use of protective gloves
because of sharp edges, ear protectors if necessary).
A sign, e.g. „Under-repair", must be attached to the system,
-
-
The safety devices may be removed,
-
The work to be carried out must not be done under time pressure,
-
The general and specific regulations on accident prevention as well as the EKAS guidelines
(Switzerland) must be observed,
-
The safety officer must be informed about the nature and course of the work,
If the intake and delivery ducts of the fan are dismounted for a longer period of time, the openings must be
closed off.
Page 10
TD-000 812-E
Edition 02/2023, Subject to alteration
Copyright by COLASIT AG Spiez
COLASIT AG
Plastics construction
CH-3700 Spiez
Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61