Temperature coefficient – when the temperature sensor is available, temperature compensation may
be performed. The number of steps per one degree of the temperature change should be entered
into this field.
Temperature compensate – enable or disable temperature compensation. The temperature
compensation cycle is 30 seconds.
Focuser
Figure 9- Focuser tab
Direction – controls the direction of the Relative position move
Relative position – allows moving the focuser by the specific amount of steps
Absolute position – allows moving the focuser to the specific position in steps
Max Position – this is the maximum outward position of the focuser in steps
Abort Motion – stop focusing motor movement immediately
Sync - synchronizes current focuser position to the specific amount of steps
Reverse Motion – reverses focuser motion, so In direction becomes Out. This setting depends on your
focuser mechanics
Backlash – implements backlash correction