MAINTENANCE
1)
Use only approved chemicals at the recommended mix ratios. All chemicals
should be added through the feed system and NOT added directly to the water in
the solution tank to prevent possible damage to the pump, seals, or other
components.
2)
For optimum performance, flush the Chemical Feed lines after every job by
replacing the chemical containers with containers of clear water and spraying
through the gun until the fluid stream is clear. See the Maintenance Schedule,
below.
3)
The pump seals and/or valves in the high pressure pumps may need to be
replaced after about 1000 hours of use, if the pump begins to loose
performance or to leak. The pressure regulator valve may need to be when a drop
in the spraying pressure at the tool is apparent.
4)
If the 4", clear lid is removed from the top of the base (solution tank), you will need to
apply a silicone sealant to the threads when you reinstall the lid to seal for vacuum
leaks.
ITEM
Flush chemical lines
Check/clean vac inlet filter
Clean solution filter
Check vacuum motor airways
Check pump for leaks
Check vacuum motor brushes *
* Have Niflisk Advance check the carbon brushes once a year or after about 500 hours of operation.

TECHNICAL SPECIFICATIONS

Vacuum motor:
Tank constructions:
Solution tank capacity:
Recovery tank: capacity:
Application flow:
Vac & Solution hose length:
Power cord:
Machine weight:

MAINTENANCE SCHEDULE

2-stage, 8 amp
Water lift:
97"
Air flow:
100 CFM
Rotationally molded polyethylene
20 gallon
12 gallon
200 psi
15 feet
25 feet
Height:
38.5 inches
Width:
21.25 inches
Length:
34 inches
92 lbs
DAILY WEEKLY QUARTELY YEARLY
x
x
x
x
x
x