6.10 SPECIFICATION TABLE
MODEL No.
Maximum Vacuum
Dimensions (L x W x H)
Port Connections
Motor
Weight
Electrical Requirements
Plug Type
Air Displacement
Maximum Pressure
OperatingTemperature Range
Humidity range:
Noise Level
Compliance
*Intermittent Duty: Limit output to 33 psig - Continuous Duty: Limit
output to 10 psig
SECTION 6: SPECIFICATION
79202-00
21.3(±0.01) in.Hg
541(±0.2) mm Hg
184.2 x 109.2x 215.3 mm
1/4" hose barb
1/11.5 hp (65w) shaded pole
115V 60Hz 1Ph
0.37 (±0.01)CFM
10.5 (±0.2) L/min
33 (±0.01) psig*
22.8X10
0~40 (°C)
10% to 90% non-condensing
≤ 70 (±2) dB @ 1 meter
UL1450,CSA C22.2,No.68
1.6kg
USA
4
Pa
(BS) EN 61000-6-2(2014/30/EU)
(BS) EN 61000-6-4(2014/30/EU)
17
79202-05
21.3(±0.01) in.Hg
541(±0.2)) mm Hg
184.2 x 109.2x 215.3 mm
1/4" hose barb
1/11.5 hp (65w) shaded pole
1.6kg
230V 50Hz 1Ph
IEC Socket, EU/UK leads
0.31 (±0.01)CFM
8.8 (±0.2) L/min
33 (±0.01) psig*
4
22.8X10
Pa
0~40 (°C)
10% to 90% non-condensing
≤ 70 (±2) dB @ 1 meter
(BS) EN 1012-2 & (BS) EN
60204(2006/42/EC)