8.4. Input Mode Read Command
Command
"CR1" [CR]
Detail
Get selected Input mode
Acceptable
Response
Unacceptable
8.5. Lamp Time Read Command
Command
"CR3" [CR]
Detail
Get total lamp running hours
Acceptable
Response
Unacceptable
8.6. Setting Read Command
Command
"CR4" [CR]
Detail
Get setting status for screen such as Ceiling / Rear
Acceptable
Response
Unacceptable
8.7. Temp Read Command
Command
"CR6" [CR]
Get the temperature inside a projector.
Detail
When some temperature sensors are installed in the projector, it is possible to
know the temperature all at once.
Acceptable
Response
%1, %2, %3
Unacceptable
Item
Status Read Command
"%1" [CR]
"1" = Computer-1 is selected
%1
"2" = Computer-2 is selected
"3" = Video is selected
"?" [CR]
"%1" [CR]
Show as 4 digits.
%1
Ex.: "0410" [CR] !410 hours
"?" [CR]
"%1" [CR]
"11" [CR] = Normal Screen Setting
"10" [CR] =
Flip vertical image
%1
"01" [CR] = Flip horizontal image (Rear ON)
"00" [CR] = Flip vertical & horizontal image (Ceiling ON)
"?" [CR]
"%1_%2_%3" [CR]
%1 = Temperature, sensor 1
%2 = Temperature, sensor 2
%3 = Temperature, sensor 3
Temperature data form shows as 00.0.
When the temperature sinks to -, the first character is "-" like
"-05.5" [CR].
When cannot return the temperature data due to hardware
problems, the first character is "E" like "E00.0" [CR].
When some temperature sensors are installed, the projector
sends command continuously.
"_31.5__35.2__33.4" [CR]
There is the first sensor's information, and after one space,
there is the second sensor's information.
"?" [CR]
(Rear&Ceiling ON)